The effects of ventricular pacing on left ventricular geometry, function, myocardial oxygen consumption, and efficiency of contraction in conscious dogs

被引:41
作者
Owen, CH
Esposito, DJ
Davis, JW
Glower, DD
机构
[1] Duke Univ, Med Ctr, Dept Surg, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Dept Biomed Engn, Durham, NC 27710 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1998年 / 21卷 / 07期
关键词
artificial pacing; ventricular performance; myocardial oxygen consumption;
D O I
10.1111/j.1540-8159.1998.tb00213.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The effects of ventricular pacing on left ventricular(LV) dynamic geometry, function, and myocardial oxygen consumption (MVO2) were measured in 12 conscious dogs using sonomicrometry, micromanometry, ultrasonic flow probes, and oximetry catheters during right atrial (A-) and right ventricular (V-) pacing at 150 beats/min. Systolic function was quantified using slopes (M-w) and volume-intercepts (V-w )of linear relationships between end-diastolic volume (EDV) and stroke work (SW) for data obtained during vena caval occlusion. V-pacing shifted SW-EDV relationships downward (M-w decreased from 97 +/- 21 to 81 +/- 22 Kerg/mL) and to the right (V-w increased from 14 +/- 11 to 20 +/- 12 mL) in comparison with A-pacing (P < 0.05). These functional changes correlated with altered contractile geometry manifest as early shortening in the septal free wall relative to anterior-posterior dimension (increased minor axis mid-wall eccentricity at end-diastole and begin-ejection). Steady-state LV power output decreased from 802 +/- 213 mW during A-pacing to 514 +/- 170 mW during V-pacing (P < 0.05), while MVO2 remained relatively unchanged during V-pacing (10 +/- 3 mL O-2/min vs 11 +/- 3 mL O-2/min during A-pacing, P = NS). As a result, overall LV efficiency decreased from 0.24 +/- 0.08 during A-pacing to 0.16 +/- 0.06 during Ir-pacing (P < 0.05). These data illustrate the impact of V-pacing on dynamic LV geometry and function, including impaired LV work output at all physiological levels of preload, Most importantly, the relationship between LV work output and MVO2 is depressed during V-pacing, emphasizing the interaction between LV mechanics and pump efficiency in intact subjects. As a result, measures taken to restore normal contractile geometry might improve LV efficiency and performance when V-pacing is necessary.
引用
收藏
页码:1417 / 1429
页数:13
相关论文
共 35 条
[1]   OBSERVATIONS ON RELATION BETWEEN VENTRICULAR ACTIVATION SEQUENCE AND HEMODYNAMIC STATE [J].
ABILDSKO.JA ;
EICH, RH ;
HARUMI, K ;
SMULYAN, H .
CIRCULATION RESEARCH, 1965, 17 (03) :236-&
[2]   ALTERATION OF LEFT-VENTRICULAR PERFORMANCE BY LEFT-BUNDLE BRANCH-BLOCK SIMULATED WITH ATRIOVENTRICULAR SEQUENTIAL PACING [J].
ASKENAZI, J ;
ALEXANDER, JH ;
KOENIGSBERG, DI ;
BELIC, N ;
LESCH, M .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (01) :99-104
[3]   EFFECTS OF VENTRICULAR PACING ON REGIONAL LEFT-VENTRICULAR PERFORMANCE IN THE DOG [J].
BADKE, FR ;
BOINAY, P ;
COVELL, JW .
AMERICAN JOURNAL OF PHYSIOLOGY, 1980, 238 (06) :H858-H867
[4]   ALTERATIONS IN LEFT-VENTRICULAR RELAXATION DURING ATRIOVENTRICULAR PACING IN HUMANS [J].
BEDOTTO, JB ;
GRAYBURN, PA ;
BLACK, WH ;
RAYA, TE ;
MCBRIDE, W ;
HSIA, HH ;
EICHHORN, EJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (03) :658-664
[5]   EFFECTS OF INDUCED ASYNCHRONY ON LEFT-VENTRICULAR DIASTOLIC FUNCTION IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
BETOCCHI, S ;
PISCIONE, F ;
VILLARI, B ;
PACE, L ;
CIARMIELLO, A ;
PERRONEFILARDI, P ;
SALVATORE, C ;
SALVATORE, M ;
CHIARIELLO, M .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (05) :1124-1131
[6]   MECHANICAL PERFORMANCE AND EFFICIENCY OF LEFT VENTRICLE DURING VENTRICULAR STIMULATION [J].
BOERTH, RC ;
COVELL, JW .
AMERICAN JOURNAL OF PHYSIOLOGY, 1971, 221 (06) :1686-&
[7]   INFLUENCE OF PACING SITE ON CANINE LEFT-VENTRICULAR CONTRACTION [J].
BURKHOFF, D ;
OIKAWA, RY ;
SAGAWA, K .
AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 251 (02) :H428-H435
[8]  
CASTRO LJ, 1992, CIRCULATION, V86, P629
[9]   RELATIVE CONTRIBUTIONS OF ATRIAL SYSTOLE-VENTRICULAR SYSTOLE INTERVAL AND OF PATTERNS OF VENTRICULAR ACTIVATION TO VENTRICULAR FUNCTION DURING ELECTRICAL PACING OF DOG HEART [J].
DAGGETT, WM ;
BIANCO, JA ;
POWELL, WJ ;
AUSTEN, WG .
CIRCULATION RESEARCH, 1970, 27 (01) :69-&
[10]   HEMODYNAMIC ALTERATIONS IN LEFT VENTRICULAR FUNCTION CONSEQUENT TO VENTRICULAR PACING [J].
FINNEY, JO .
AMERICAN JOURNAL OF PHYSIOLOGY, 1965, 208 (02) :275-&