摘要
The myelin water fraction is calculated, voxel-by-voxel, by fitting decay curves from a multi-echo data acquisition. Curve-fitting algorithms require a high signal-to-noise ratio to separate T-2 components in the T-2 distribution. This work compared the effect of averaging, during acquisition, to data postprocessed with a noise reduction filter. Forty regions, from five volunteers, were analyzed. A consistent decrease in the myelin water fraction variability with no bias in the mean was found for all 40 regions. Images of the myelin water fraction of white matter were more contiguous and had fewer "holes" than images of myelin water fractions from unfiltered echoes. Spatial filtering was effective for decreasing the variability in myelin water fraction calculated from 4-average multi-echo data. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:206 / 209
页数:4
相关论文
共 16 条
[1]  
[Anonymous], 1986, Statistical Science, DOI [10.1214/ss/1177013815, DOI 10.1214/SS/1177013815]
[2]   NONLINEAR ANISOTROPIC FILTERING OF MRI DATA [J].
GERIG, G ;
KUBLER, O ;
KIKINIS, R ;
JOLESZ, FA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (02) :221-232
[3]   Criteria for analysis of multicomponent tissue T-2 relaxation data [J].
Graham, SJ ;
Stanchev, PL ;
Bronskill, MJ .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (03) :370-378
[4]   THE RICIAN DISTRIBUTION OF NOISY MRI DATA [J].
GUDBJARTSSON, H ;
PATZ, S .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) :910-914
[5]  
Lawson C.L., 1974, SOLVING LEAST SQUARE
[6]   IN-VIVO VISUALIZATION OF MYELIN WATER IN BRAIN BY MAGNETIC-RESONANCE [J].
MACKAY, A ;
WHITTALL, K ;
ADLER, J ;
LI, D ;
PATY, D ;
GRAEB, D .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (06) :673-677
[7]  
MACKIEWICH B, 1995, THESIS S FRASER U
[8]   APPLICATION OF CONTINUOUS RELAXATION-TIME DISTRIBUTIONS TO THE FITTING OF DATA FROM MODEL SYSTEMS AND EXCISED TISSUE [J].
MENON, RS ;
ALLEN, PS .
MAGNETIC RESONANCE IN MEDICINE, 1991, 20 (02) :214-227
[9]   Quantification of multiple sclerosis lesion volumes in 1.5 and 0.5 T anisotropically filtered and unfiltered MR exams [J].
Mitchell, JR ;
Karlik, SJ ;
Lee, DH ;
Eliasziw, M ;
Rice, GP ;
Fenster, A .
MEDICAL PHYSICS, 1996, 23 (01) :115-126
[10]   Improved vessel visualization in MR angiography by nonlinear anisotropic filtering [J].
Orkisz, MM ;
Bresson, C ;
Magnin, IE ;
Champin, O ;
Douek, PC .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (06) :914-919