Determination of histamine by high-pH anion-exchange chromatography with electrochemical detection

被引:21
作者
Casella, IG
Gatta, M
Desimoni, E
机构
[1] Univ Basilicata, Dipartimento Chim, I-85100 Potenza, Italy
[2] Univ Milan, Dipartimento Prod Vegetale, I-20133 Milan, Italy
关键词
histamine; electrochemical detection; copper electrode; tuna; wine;
D O I
10.1016/S0308-8146(01)00117-0
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A simple, sensitive and rapid method is described for determining histamine in alkaline media by anion-exchange chromatography with amperometric detection at a copper-based modified glassy carbon electrode. The influence of copper loading, applied potential and flow rate on the amperometric signal was evaluated. Under optimal chromatographic conditions, the detection limit for histamine (S/N = 3) was 0.1 muM (corresponding to 5 pmol injected by a 50-mul sample loop). The linear range spanned from 5 to 500 muM (correlation coefficient = 0.998). The proposed method allows a rapid and convenient quantitation of histamine in real matrices, such as canned tuna and red wine, without time-consuming clean-up or derivatisation procedures. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:367 / 372
页数:6
相关论文
共 22 条
[1]  
ARNOLD SH, 1978, ADV FOOD RES, V34, P113
[2]   Anodic electrodeposition of copper oxide/hydroxide films by alkaline solutions containing cuprous cyanide ions [J].
Casella, IG ;
Gatta, M .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2000, 494 (01) :12-20
[3]  
Casella IG, 1998, ELECTROANAL, V10, P1005, DOI 10.1002/(SICI)1521-4109(199810)10:15<1005::AID-ELAN1005>3.0.CO
[4]  
2-R
[5]   ENZYME-IMMUNOASSAY FOR THE MEASUREMENT OF HISTAMINE [J].
CHEVRIER, D ;
GUESDON, JL ;
MAZIE, JC ;
AVRAMEAS, S .
JOURNAL OF IMMUNOLOGICAL METHODS, 1986, 94 (1-2) :119-125
[6]   Pulsed electrochemical detection at gold electrodes applied to monoamines and diamines following their chromatographic separation [J].
Dobberpuhl, DA ;
Hoekstra, JC ;
Johnson, DC .
ANALYTICA CHIMICA ACTA, 1996, 322 (1-2) :55-62
[7]   Electrooxidation of ammonia and simple amines at titanium electrodes modified with a mixture of ruthenium and titanium dioxides [J].
Donten, M ;
Hyk, W ;
Ciszkowska, M ;
Stojek, Z .
ELECTROANALYSIS, 1997, 9 (10) :751-754
[8]   AN IMMUNOASSAY FOR HISTAMINE BASED ON MONOCLONAL-ANTIBODIES [J].
HAMMAR, E ;
BERGLUND, A ;
HEDIN, A ;
NORRMAN, A ;
RUSTAS, K ;
YTTERSTROM, U ;
AKERBLOM, E .
JOURNAL OF IMMUNOLOGICAL METHODS, 1990, 128 (01) :51-58
[9]  
Hoekstra MF, 1998, FASEB J, V12, pA1320
[10]   Electrochemical oxidation of polyamines at diamond thin-film electrodes [J].
Koppang, MD ;
Witek, M ;
Blau, J ;
Swain, GM .
ANALYTICAL CHEMISTRY, 1999, 71 (06) :1188-1195