Evaluating the validity of clinical codes to identify cataract and glaucoma in the UK Clinical Practice Research Datalink

被引:17
作者
Kang, Elizabeth M. [1 ]
Pinheiro, Simone P. [1 ]
Hammad, Tarek A. [1 ]
Abou-Ali, Adel [1 ]
机构
[1] US FDA, Silver Spring, MD 20993 USA
关键词
clinical practice research datalink; read codes; validation of cataract; validation of glaucoma; eye disorders; pharmacoepidemiology; PRACTICE RESEARCH DATABASE; PREDICTIVE-VALUE; RISK; POPULATION; STATINS; CORTICOSTEROIDS; DISEASE; USERS;
D O I
10.1002/pds.3726
中图分类号
R1 [预防医学、卫生学];
学科分类号
100235 [预防医学];
摘要
PurposeThe aim of this study is to determine (i) the positive predictive value (PPV) of an algorithm using clinical codes to identify incident glaucoma and cataract events in the Clinical Practice Research Datalink (CPRD) and (ii) the ability to capture the correct timing of these clinical events. MethodsA total of 21339 and 5349 potential cataract and glaucoma cases, respectively, were identified in CPRD between 1 January 1990 and 31 December 2010. Questionnaires were sent to the general practitioners (GP) of 1169 (5.5%) cataract and 1163 (21.7%) glaucoma cases for validation. GPs were asked to verify the diagnosis and the timing of the diagnosis and to provide other supporting information. ResultsA total of 986 (84.3%) valid cataract questionnaires and 863 (74.2%) glaucoma questionnaires were completed. 92.1% and 92.4% of these used information beyond EMR to verify the diagnosis. Cataract and glaucoma diagnoses were confirmed in the large majority of the cases. The PPV (95% CI) of the cataract and glaucoma Read code algorithm were 92.0% (90.3-93.7%) and 84.1% (81.7-86.6%), respectively. However, timing of diagnosis was incorrect for a substantial proportion of the cases (20.3% and 32.8% of the cataract and glaucoma cases, respectively) among whom 30.4% and 49.2% had discrepancies in diagnosis timing greater than 1year. ConclusionsHigh PPV suggests that the algorithms based on the clinical Read codes are sufficient to identify the cataract and glaucoma cases in CPRD. However, these codes alone may not be able to accurately identify the timing of the diagnosis of these eye disorders. Copyright (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:38 / 44
页数:7
相关论文
共 17 条
[1]
Hormone replacement therapy and cataract: a population-based case-control study [J].
Aina, FO ;
Smeeth, L ;
Hubbard, R ;
Hurt, LS ;
Fletcher, AE .
EYE, 2006, 20 (04) :417-422
[2]
Association of Optometrists, 2001, PRIM EYECAR COMM
[3]
Tamoxifen and cataracts: a null association [J].
Bradbury, BD ;
Lash, TL ;
Kaye, JA ;
Jick, SS .
BREAST CANCER RESEARCH AND TREATMENT, 2004, 87 (02) :189-196
[4]
Clinical Practice Research Datalink, 2014, BIBL RES PAP
[5]
Risk of cataract among users of intranasal corticosteroids [J].
Derby, L ;
Maier, WC .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2000, 105 (05) :912-916
[6]
Determining the predictive value of Read codes to identify congenital cardiac malformations in the UK Clinical Practice Research Datalink [J].
Hammad, Tarek A. ;
Margulis, Andrea V. ;
Ding, Yulan ;
Strazzeri, Marian M. ;
Epperly, Holly .
PHARMACOEPIDEMIOLOGY AND DRUG SAFETY, 2013, 22 (11) :1233-1238
[7]
Determining the predictive value of Read/OXMIS codes to identify incident acute myocardial infarction in the General Practice Research Database [J].
Hammad, Tarek A. ;
McAdams, Mara A. ;
Feight, Andrea ;
Iyasu, Solomon ;
Dal Pan, Gerald J. .
PHARMACOEPIDEMIOLOGY AND DRUG SAFETY, 2008, 17 (12) :1197-1201
[8]
Validation and validity of diagnoses in the General Practice Research Database: a systematic review [J].
Herrett, Emily ;
Thomas, Sara L. ;
Schoonen, W. Marieke ;
Smeeth, Liam ;
Hall, Andrew J. .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2010, 69 (01) :4-14
[9]
The risk of obstructive airways disease in a glaucoma population [J].
Huerta, C ;
Rodríguez, LAG ;
Möller, CS ;
Arellano, FM .
PHARMACOEPIDEMIOLOGY AND DRUG SAFETY, 2001, 10 (02) :157-163
[10]
The risk of cataract among users of inhaled steroids [J].
Jick, SS ;
Vasilakis-Scaramozza, C ;
Maier, WC .
EPIDEMIOLOGY, 2001, 12 (02) :229-234