Intraoperative Ultrasonography-Guided Excision of Nonpalpable Breast Lesions

被引:5
作者
Bennett, Ian [1 ]
Biggar, Magdalena [1 ]
机构
[1] Univ Queensland, Princess Alexandra Hosp, Breast & Endocrine Surg Unit, Brisbane, Qld 4102, Australia
关键词
ULTRASOUND LOCALIZATION; NEEDLE LOCALIZATION; OCCULT LESION; CANCER; SURGERY; BIOPSY; LUMPECTOMY;
D O I
10.1007/s00268-011-1082-y
中图分类号
R61 [外科手术学];
学科分类号
100210 [外科学];
摘要
Background The use of intraoperative ultrasonography (US) to localize and guide excision of nonpalpable breast lesions has advantages over other techniques. It avoids the need for additional resources and minimizes patient morbidity. Methods and results The technique of surgeon-performed US-guided excision as described in this report is straightforward and safe, easily reproducible, and suitable for teaching. Conclusions The US-guided breast excision technique is predictable and accurate, minimizes costs, and is advocated as an appropriate method for US-visible lesions requiring surgical excision. With appropriate training, breast surgeons can easily acquire the necessary skills to incorporate the use of US in their surgical practice.
引用
收藏
页码:1835 / 1839
页数:5
相关论文
共 21 条
[1]
Intraoperative ultrasound-guided excision of nonpalpable breast lesions [J].
Bennett, IC ;
Greenslade, J ;
Chiam, H .
WORLD JOURNAL OF SURGERY, 2005, 29 (03) :369-374
[2]
Breast intraoperative ultrasound: Prospective study in 112 patients with impalpable lesions [J].
Buman, SJ ;
Clark, DA .
ANZ JOURNAL OF SURGERY, 2005, 75 (03) :124-127
[3]
Canavese G, 1995, Eur J Surg Oncol, V21, P47, DOI 10.1016/S0748-7983(05)80067-8
[4]
Wire-directed localization biopsy of the breast: An audit of results and analysis of factors influencing therapeutic value in the treatment of breast cancer [J].
Chadwick, DR ;
Shorthouse, AJ .
EUROPEAN JOURNAL OF SURGICAL ONCOLOGY, 1997, 23 (02) :128-133
[5]
Updates in breast ultrasound [J].
Fine, RE ;
Staren, ED .
SURGICAL CLINICS OF NORTH AMERICA, 2004, 84 (04) :1001-+
[6]
A novel ultrasound-guided electrosurgical loop device for intra-operative excision of breast lesions; an improvement in surgical technique [J].
Fine, Richard E. ;
Schwalke, Michael A. ;
Pellicane, James V. ;
Attai, Deanna J. .
AMERICAN JOURNAL OF SURGERY, 2009, 198 (02) :283-286
[7]
FORTUNATO L, 2008, EJSO, V24, P1289
[8]
Single-step ultrasound localization of breast lesions and lumpectomy procedure [J].
Gittleman, MA .
AMERICAN JOURNAL OF SURGERY, 2003, 186 (04) :386-390
[9]
HOMER MJ, 1992, RADIOL CLIN N AM, V30, P139
[10]
Intraoperative Ultrasound Versus Mammographic Needle Localization for Ductal Carcinoma In Situ [J].
James, T. A. ;
Harlow, S. ;
Sheehey-Jones, J. ;
Hart, M. ;
Gaspari, C. ;
Stanley, M. ;
Krag, D. ;
Ashikaga, Takamaru ;
McCahill, L. E. .
ANNALS OF SURGICAL ONCOLOGY, 2009, 16 (05) :1164-1169