Short-circuit tests on a high-voltage, cable-wound hydropower generator

被引:15
作者
Johansson, SG [1 ]
Larsson, B
机构
[1] ABB Corp Res, SE-72178 Vasteras, Sweden
[2] ALSTOM Power Generat, SE-72176 Vasteras, Sweden
关键词
powerformer; short-circuit measurements;
D O I
10.1109/TEC.2003.821829
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Data from measurements on the first Powerformer generator installed in Porjus, Sweden, will be-presented. The generator has a rating of 45 kV and 11 MVA. In total, the machine has been running more than 13700 h (October 2001) and has been exposed to a number of different tests including short-circuit tests on the terminal at 100% magnetization. Experience and some results from these short-circuit tests will be presented. Also, the response on the auxiliary winding during a short circuit on the main winding will be shown.
引用
收藏
页码:28 / 33
页数:6
相关论文
共 8 条
[1]  
HOLMBERG P, UNPUB IEEE T CONVESI
[2]  
IMRELL AM, 2000, P INT S TRANS PHEN D, V2, P614
[3]   COMPUTER SOFTWARE TO AUTOMATE THE GRAPHICAL ANALYSIS OF SUDDEN-SHORT-CIRCUIT OSCILLOGRAMS OF LARGE SYNCHRONOUS MACHINES [J].
KAMWA, I ;
CARLE, H ;
VIAROUGE, P ;
MPANDAMABWE, B ;
PILOTE, M ;
CRAPPE, M .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1995, 10 (03) :399-406
[4]  
LEIJON M, 2000, P CENTR BOARD IRR PO
[5]  
LEIJON M, 1998, P CIRGRE SESS PAR FR
[6]   MEASUREMENT OF CABLE SWITCHING TRANSIENTS IN UNDERGROUND DISTRIBUTION-SYSTEMS [J].
WALLING, RA ;
MELCHIOR, RD ;
MCDERMOTT, BA .
IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (01) :534-539
[7]  
*WILL WAT, 1956, NEUTR GROUND HIGH VO
[8]  
Willheim R., 1936, ERDSCHLUSSPROBLEM HO