On-line liquid-liquid extraction system using a new phase separator for flame atomic absorption spectrometric determination of ultra-trace cadmium in natural waters

被引:130
作者
Anthemidis, AN [1 ]
Zachariadis, GA [1 ]
Farastelis, CG [1 ]
Stratis, JA [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Analyt Chem Lab, Thessaloniki 54124, Greece
关键词
cadmium; flow injection; liquid-liquid extraction; atomic absorption spectrometry; phase separator;
D O I
10.1016/j.talanta.2003.07.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A robust flow injection (FI) on-line liquid-liquid extraction (LLE) preconcentration/separation system associated with a newly designed gravitational phase separator, coupled to flame atomic absorption spectrometry (FAAS) was developed. The performance of the system was illustrated for cadmium determination at the mug l(-1) level. The non-charged cadmium complex with ammonium pyrrolidine dithiocarbamate (APDC) was extracted on-line into isobutyl methyl ketone (IBMK). The organic phase was effectively separated from a large volume of aqueous phase and is led into a 100 mul loop of an injection valve before its introduction into the nebulizer. The system was optimized and offered good performance characteristics with unlimited life time of phase separator, greater flow rate ratios and improved flexibility, as compared with other solvent extraction preconcentration systems. With a sampling frequency of 33 h(-1), the enhancement factor was 155, the detection limit was 0.02 mug l(-1), the relative standard deviation was 3.2% at 2.0 mug l(-1) Cd concentration level and the calibration curve was linear over the concentration range 0.06-6.0 mug l(-1). The accuracy of the proposed method was evaluated by analyzing a certified reference material of water and by recovery measurements on spiked samples. Finally, it was successfully applied to the analysis of tapwater, river and seawater samples. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:437 / 443
页数:7
相关论文
共 15 条
[1]  
APHA AWWA WEF, 1995, STAND METH EX WAT WA
[2]   DESIGN OF A CONTINUOUS-FLOW 2-STEP EXTRACTION SAMPLE WORK-UP SYSTEM FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BACKSTROM, K ;
DANIELSSON, LG .
ANALYTICA CHIMICA ACTA, 1990, 232 (02) :301-315
[3]  
Cresser M. S., 1978, SOLVENT EXTRACTION F
[4]  
Fang Z., 1995, FLOW INJECTION ATOMI
[5]   Design and application of a new phase separator for flow injection liquid-liquid extraction [J].
Lin, SL ;
Qin, SA ;
Qiu, HO ;
Tang, ZY .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (14) :1769-1775
[6]   THE DESIGN OF AN ONLINE FLOW-INJECTION SYSTEM WITH A GRAVITATIONAL PHASE SEPARATOR FOR FLAME ATOMIC-ABSORPTION SPECTROMETRY AND ITS ANALYTICAL PERFORMANCE [J].
LIN, SL ;
HWANG, HP .
TALANTA, 1993, 40 (07) :1077-1083
[7]   DETERMINATION OF COPPER AND CADMIUM IN SEA-WATER BY PRECONCENTRATION AND ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
LIU, ZS ;
HUANG, SD .
ANALYTICA CHIMICA ACTA, 1992, 267 (01) :31-37
[8]   SPECTROPHOTOMETRIC DETERMINATION OF PHOSPHORUS AS ORTHO-PHOSPHATE BASED ON SOLVENT-EXTRACTION OF THE ION ASSOCIATE OF MOLYBDOPHOSPHATE WITH MALACHITE GREEN USING FLOW-INJECTION [J].
MOTOMIZU, S ;
OSHIMA, M .
ANALYST, 1987, 112 (03) :295-300
[9]   AN AUTOMATED EXTRACTION SYSTEM FOR FLAME ATOMIC-ABSORPTION SPECTROMETRY [J].
NORD, L ;
KARLBERG, B .
ANALYTICA CHIMICA ACTA, 1981, 125 (APR) :199-202
[10]   SAMPLE PRE-CONCENTRATION BY CONTINUOUS-FLOW EXTRACTION WITH A FLOW-INJECTION ATOMIC-ABSORPTION DETECTION SYSTEM [J].
NORD, L ;
KARLBERG, B .
ANALYTICA CHIMICA ACTA, 1983, 145 (JAN) :151-158