Purpose: To compare infusion and extrusion fluid volumes with three 25-gauge vitrectomy systems. Methods: The infusion and aspiration rates of 25-gauge systems from Alcon (Fort Worth, TX, USA), Bausch & Lomb (St Louis, MO, USA), and the Dutch Ophthalmic Research Centre (DORC, Zuidland, the Netherlands) were measured in vitro using balanced saline solution with different heights (40, 609 80, 100, 120 cm) of infusion bottle, cutter velocities (800, 1100, 1500 cuts/min) and aspiration powers (100, 200, 300, 400, 500 mmHg). Results: The infusion flow velocities differed among the systems (p < 0.001 for all comparisons lp-values 0.0009-0.00011). The aspiration rates of the Alcon and Bausch & Lomb systems were lower than that of the DORC system (p < 0.02 for all comparisons lp-values 0.018-0.0021). Conclusions: Infusion and extrusion fluid rates differ among 25-gauge vitrectomy systems. These results may help to optimize ideal aspiration and infusion parameters among 25-gauge vitrectomy systems used to treat vitreoretinal diseases.
引用
收藏
页码:156 / 159
页数:4
相关论文
共 14 条
  • [1] An engineering approach to vitreoretinal surgery
    Charles, S
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2004, 24 (03): : 435 - 444
  • [2] Sutureless pars plana vitrectomy through self-sealing sclerotomies
    Chen, JC
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1996, 114 (10) : 1273 - 1275
  • [3] REFINEMENTS IN MICROINSTRUMENTATION FOR VITREOUS SURGERY
    DEJUAN, E
    HICKINGBOTHAM, D
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1990, 109 (02) : 218 - 220
  • [4] Initial experience using the Transconjunctival Sutureless Vitrectomy System for vitreoretinal surgery
    Fujii, GY
    de Juan, E
    Humayun, MS
    Chang, TS
    Pieramici, DJ
    Barnes, A
    Kent, D
    [J]. OPHTHALMOLOGY, 2002, 109 (10) : 1814 - 1820
  • [5] A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery
    Fujii, GY
    de Juan, E
    Humayun, MS
    Pieramici, DJ
    Chang, TS
    Ng, E
    Barnes, A
    Wu, SL
    Sommerville, DN
    [J]. OPHTHALMOLOGY, 2002, 109 (10) : 1807 - 1812
  • [6] Hasumura T, 2000, INVEST OPHTH VIS SCI, V41, P4300
  • [7] Effect of infusion air pressure on visual field defects after macular hole surgery
    Hirata, A
    Yonemura, N
    Hasumura, T
    Murata, Y
    Negi, A
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 130 (05) : 611 - 616
  • [8] Modified sutureless sclerotomies in pars plana vitrectomy
    Jackson, T
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (01) : 116 - 117
  • [9] KAZUHIRO O, 2001, AM J OPHTHALMOL, V131, P814
  • [10] Modified sutureless sclerotomies in pars plana vitrectomy
    Kwok, AKH
    Tham, CCY
    Lam, DSC
    Li, M
    Chen, JC
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 127 (06) : 731 - 733