Characterization of raw water for the ozone application measuring ozone consumption rate

被引:74
作者
Park, HS
Hwang, TM
Kang, JW
Choi, H
Oh, HJ
机构
[1] Yonsei Univ, Dept Environm Engn, Wonju 220710, South Korea
[2] Kwangju Inst Sci & Technol, Dept Environm Sci & Engn, Kwangju 500712, South Korea
[3] Korea Inst Construct Technol, Ilsan Gu 411417, Kyonggi Do, South Korea
关键词
ozone; ozone-decomposition kinetics; instantaneous ozone demand; pseudo first-order decay rate; water characterization; OH center dot;
D O I
10.1016/S0043-1354(00)00564-9
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study was conducted to illustrate an ideal method For characterizing natural waters for ozonation processes in drinking water treatment plants. A specific instrument designed with the flow injection analysis (FIA) technique enabled us to measure accurately the ozone decomposition rate, which was found to consist of two stages: the instantaneous ozone consumption stage and the slower ozone decay stage. The ozone consumption rate was measured at the initial and secondary stages by determining certain parameters called the instantaneous ozone demand (ID) and the pseudo first-order decay rate constant (k(c)). Using the OH . -probe the yield of OH . per consumed ozone was also measured to determine its potential ti, produce OH . for the oxidation of micropollutants during the ozonation process. The ozone consumption of the ID values was significant in most natural waters, and substantial amounts of OH . were found to generate during the instantaneous ozone consumption stage. This study also investigated the effects of particulates, ozone doses, and sequential ozone injection on ozone decomposition kinetics and OH . formation yield. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:2607 / 2614
页数:8
相关论文
共 22 条
[1]   DETERMINATION OF OZONE IN WATER BY THE INDIGO METHOD [J].
BADER, H ;
HOIGNE, J .
WATER RESEARCH, 1981, 15 (04) :449-456
[2]  
BEZBARUA BK, 1998, P 13 OZ WORLD C OCT, V1, P337
[3]  
BUHLER RE, 1984, J PHYS CHEM-US, V88, P2560
[4]   CRITICAL-REVIEW OF RATE CONSTANTS FOR REACTIONS OF HYDRATED ELECTRONS, HYDROGEN-ATOMS AND HYDROXYL RADICALS (.OH/.O-) IN AQUEOUS-SOLUTION [J].
BUXTON, GV ;
GREENSTOCK, CL ;
HELMAN, WP ;
ROSS, AB .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 1988, 17 (02) :513-886
[5]   NUMERICAL SIMULATIONS OF AQUEOUS OZONE DECOMPOSITION [J].
CHELKOWSKA, K ;
GRASSO, D ;
FABIAN, I ;
GORDON, G .
OZONE-SCIENCE & ENGINEERING, 1992, 14 (01) :33-49
[6]  
CHOI HC, 2000, IN PRESS WATER SCI T
[7]   Hydroxyl radical ozone ratios during ozonation processes.: I-The Rct concept [J].
Elovitz, MS ;
von Gunten, U .
OZONE-SCIENCE & ENGINEERING, 1999, 21 (03) :239-260
[8]  
ELOVITZ MS, 1998, P 13 OZ WORLD C OCT, V1, P475
[9]  
ELOVITZ MS, 1999, P 14 OZ WORLD C AUG, V2, P95
[10]   MECHANISM OF THE HYDROXIDE ION INITIATED DECOMPOSITION OF OZONE IN AQUEOUS-SOLUTION [J].
FORNI, L ;
BAHNEMANN, D ;
HART, EJ .
JOURNAL OF PHYSICAL CHEMISTRY, 1982, 86 (02) :255-259