Diagnostic benefit of echocontrast enhancement for the insufficient transtemporal bone window

被引:20
作者
Nabavi, DG [1 ]
Droste, DW [1 ]
Schulte-Altedorneburg, G [1 ]
Kemény, V [1 ]
Panzica, M [1 ]
Weber, S [1 ]
Ringelstein, EB [1 ]
机构
[1] Univ Munster, Dept Neurol, D-48129 Munster, Germany
关键词
echocontrast agents; echoenhancement; diagnostic ultrasonography; bone window;
D O I
10.1111/jon199992102
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Echocontrast agents (ECA) are known to improve transcranial color-coded duplex (TCCD) imaging, but its diagnostic benefit in the routine clinical setting has not clearly been defined. The authors investigated the diagnostic benefit of ECA application in 54 patients with insufficient transtemporal bone window, consecutively referred to their ultrasound laboratory. According to the precontrast imaging quality, patients were assigned to three categories: A, no intracranial structures or vessel segments visible on B-mode imaging and TCCD (n = 5); and intracranial structures visible on B-mode imaging and Vessel segments less than 5 mm in length (B, n = 21), or larger than 5 mm in length (C, n = 28) visible on TCCD. The effect of the echocontrast enhancement was assessed with respect to signal enhancement, imaging quality, and diagnostic confidence. In 49 out of 54 patients (91%), a significant improvement of the imaging quality was noted, enabling 43 (80%) neurovascular diagnoses of sufficient diagnostic confidence. The diagnostic ECA effect was strongly dependent on the precontrast imaging quality: upon echoenhancement, a satisfactory image quality was obtained in none of the patients of category A, as opposed to 16 (76%) and 27 (96%) patients of categories B and C, respectively. in summary, in 80% of our consecutive patient series with insufficient transtemporal bone window, application of ECA allowed for a conclusive TCCD study. Properties of the transtemporal precontrast scans are strongly predictive of the diagnostic benefit and should be taken into the decisive consideration.
引用
收藏
页码:102 / 107
页数:6
相关论文
共 18 条
[1]   NON-INVASIVE TRANSCRANIAL DOPPLER ULTRASOUND RECORDING OF FLOW VELOCITY IN BASAL CEREBRAL-ARTERIES [J].
AASLID, R ;
MARKWALDER, TM ;
NORNES, H .
JOURNAL OF NEUROSURGERY, 1982, 57 (06) :769-774
[2]   Comparative study of power-based versus mean frequency-based transcranial color-coded duplex sonography in normal adults [J].
Baumgartner, RW ;
Schmid, C ;
Baumgartner, I .
STROKE, 1996, 27 (01) :101-104
[3]   Transcranial color-coded duplex sonography in arterial cerebrovascular disease [J].
Baumgartner, RW ;
Mattle, HP ;
Aaslid, R ;
Kaps, M .
CEREBROVASCULAR DISEASES, 1997, 7 (02) :57-63
[4]   CONTRAST-ENHANCED TRANSCRANIAL COLOR-CODED REAL-TIME SONOGRAPHY - RESULTS OF A PHASE-2 STUDY [J].
BOGDAHN, U ;
BECKER, G ;
SCHLIEF, R ;
REDDIG, J ;
HASSEL, W .
STROKE, 1993, 24 (05) :676-684
[5]  
Burns PN, 1997, J NEUROIMAGING, V7, pS2
[6]   Power Doppler ultrasound examination of the intracerebral and extracerebral vasculature [J].
Griewing, B ;
Doherty, C ;
Kessler, C .
JOURNAL OF NEUROIMAGING, 1996, 6 (01) :32-35
[7]   PHASE .1. TRANSCRANIAL ECHO CONTRAST STUDIES IN HEALTHY-VOLUNTEERS [J].
KAPS, M ;
SCHAFFER, P ;
BELLER, KD ;
SEIDEL, G ;
BLIESATH, H ;
WURST, W .
STROKE, 1995, 26 (11) :2048-2052
[8]   TRANSCRANIAL DOPPLER ULTRASOUND FINDINGS IN MIDDLE CEREBRAL-ARTERY OCCLUSION [J].
KAPS, M ;
DAMIAN, MS ;
TESCHENDORF, U ;
DORNDORF, W .
STROKE, 1990, 21 (04) :532-537
[9]  
KAPS M, 1994, EXTRA INTRAKRANIELLE
[10]   Power Doppler: An advance over colour Doppler for transcranial imaging? [J].
Kenton, AR ;
Martin, PJ ;
Evans, DH .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (03) :313-317