The clinical need for high-sensitivity cardiac troponin assays for acute coronary syndromes and the role for serial testing

被引:132
作者
Wu, Alan H. B. [1 ]
Jaffe, Allan S. [2 ,3 ]
机构
[1] Univ Calif San Francisco, San Francisco Gen Hosp, Dept Lab Med, Clin Chem Lab, San Francisco, CA 94110 USA
[2] Mayo Clin, Div Cardiovasc, Rochester, MN USA
[3] Mayo Clin, Div Lab Med, Rochester, MN USA
关键词
D O I
10.1016/j.ahj.2007.10.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Cardiac troponin is the biomarker of choice for the serologic diagnosis of acute coronary syndromes. International cardiology and laboratory medicine guidelines have suggested that the cutoff concentration be set at the 99th percentile of a healthy population, with an assay imprecision of 10% or less. Unfortunately, most commercial troponin assays do not have the sensitivity and precision to reliably detect troponin in sera of healthy subjects. Therefore, there is a need to develop troponin assays with higher sensitivity, which cannot be achieved while also improving the assay's precision. Methods and Results Novel prototype analytical testing devices have been developed that are 5- to 10-fold more sensitive than existing commercial troponin assays. These tests should enable an earlier detection of myocardial infarction relative to the time of presentation and detect a higher percentage of emergency department chest pain patients who are at risk for short-term major adverse cardiac events. However, use of a high-sensitivity troponin assay will also result in detection of more patients who have cardiac necrosis due to a nonischemic etiology. Conclusions Serial troponin testing will be necessary to determine the clinical significance of low levels of troponin release with use of high-sensitivity assays. Guidelines will need to be established to determine a change in troponin results that is statistically and clinically significant, and new considerations for the time interval needed between blood collections. This will enable the use of future high-sensitivity troponin assays to be more valuable.
引用
收藏
页码:208 / 214
页数:7
相关论文
共 41 条
[1]   CARDIAC TROPONIN-I - A MARKER WITH HIGH SPECIFICITY FOR CARDIAC INJURY [J].
ADAMS, JE ;
BODOR, GS ;
DAVILAROMAN, VG ;
DELMEZ, JA ;
APPLE, FS ;
LADENSON, JH ;
JAFFE, AS .
CIRCULATION, 1993, 88 (01) :101-106
[2]   Myocardial infarction redefined -: A consensus Document of the Joint European Society of Cardiology/American College of Cardiology Committee for the Redefinition of Myocardial Infarction [J].
Alpert, JS ;
Antman, E ;
Apple, F ;
Armstrong, PW ;
Bassand, JP ;
de Luna, AB ;
Beller, G ;
Breithardt, G ;
Chaitman, BR ;
Clemmensen, P ;
Falk, E ;
Fishbein, MC ;
Galvani, M ;
Garson, A ;
Grines, C ;
Hamm, C ;
Jaffe, A ;
Katus, H ;
Kjekshus, J ;
Klein, W ;
Klootwijk, P ;
Lenfant, C ;
Levy, D ;
Levy, RI ;
Luepker, R ;
Marcus, F ;
Näslund, U ;
Ohman, M ;
Pahlm, O ;
Poole-Wilson, P ;
Popp, R ;
Alto, P ;
Pyörälä, K ;
Ravkilde, J ;
Rehnquist, N ;
Roberts, W ;
Roberts, R ;
Roelandt, J ;
Rydén, L ;
Sans, S ;
Simoons, ML ;
Thygesen, K ;
Tunstall-Pedoe, H ;
Underwood, R ;
Uretsky, BF ;
Van de Werf, F ;
Voipio-Pulkki, LM ;
Wagner, G ;
Wallentin, L ;
Wijns, W .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (03) :959-969
[3]   Clinical impact of the troponin 99th percentile cut-off and clinical utility of myoglobin measurement in the early management of chest pain patients admitted to the Emergency Cardiology Department [J].
Amodio, Gianfranco ;
Antonelli, Gianfranco ;
Varraso, Lucia ;
Ruggieri, Vincenzo ;
Di Serio, Francesca .
CORONARY ARTERY DISEASE, 2007, 18 (03) :181-186
[4]  
[Anonymous], 1979, Circulation, V59, P607
[5]   Serum and plasma cardiac troponin I 99th percentile reference values for 3 2nd-generation assays [J].
Apple, Fred S. ;
Murakarni, MaryAnn M. .
CLINICAL CHEMISTRY, 2007, 53 (08) :1558-1560
[6]   Validation of the 99th percentile cutoff independent of assay imprecision (CV) for cardiac troponin monitoring for ruling out myocardial infarction [J].
Apple, FS ;
Parvin, CA ;
Buechler, KF ;
Christenson, RH ;
Wu, AHB ;
Jaffe, AS .
CLINICAL CHEMISTRY, 2005, 51 (11) :2198-2200
[7]   Serum 99th percentile reference cutoffs for seven cardiac troponin assays [J].
Apple, FS ;
Murakami, MM .
CLINICAL CHEMISTRY, 2004, 50 (08) :1477-1479
[8]   Predictive value of cardiac troponin I and T for subsequent death in end-stage renal disease [J].
Apple, FS ;
Murakami, MM ;
Pearce, LA ;
Herzog, CA .
CIRCULATION, 2002, 106 (23) :2941-2945
[9]   Troponin: the biomarker of choice for the detection of cardiac injury [J].
Babuin, L ;
Jaffe, AS .
CANADIAN MEDICAL ASSOCIATION JOURNAL, 2005, 173 (10) :1191-1202
[10]  
BAO P, 2007, 2 INT S INT BIOM CAR