Characterization of the fussed discharge electron capture detector

被引:17
作者
Cai, HM [1 ]
Wentworth, WE [1 ]
Stearns, SD [1 ]
机构
[1] UNIV HOUSTON,DEPT CHEM,HOUSTON,TX 77204
关键词
D O I
10.1021/ac951047j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new version of the pulsed discharge electron capture detector (PDECD) has been developed and characterized. Changes to the old version include a slightly altered detector geometry, replacement of the polymer insulation with sapphire and quartz, and the use of methane dopant gas instead of nitrogen or hydrogen. Various operating parameters have been investigated and optimized, including discharge current, dopant gas, bias voltage, and sample introduction position. The resulting detector is more inert and more sensitive (a limit of 36 fg for lindane) and capable of operation at temperatures as high as 400 degrees C. By running 23 halocarbon compounds on the improved PDECD and on a Ni-63-ECD using the same GC system, we find that the PDECD is superior to Ni-63-ECD in terms of sensitivity, linearity, and response time. We attribute the enhanced sensitivity to a lower positive ion concentration, which its turn lowers the electron-positive ion rate of recombination. Pesticides (including some real-world samples) have also been analyzed on the PDECD. The results demonstrate that the PDECD can replace the radioactive ECD typically used in these analyses.
引用
收藏
页码:1233 / 1244
页数:12
相关论文
共 13 条
[1]  
BOCHINSKI JH, 1964, 148 NAT M AM CHEM SO, pA22
[2]  
CAI H, 1993, THESIS TU HOUSTON HO
[3]  
FREEMAN RR, 1971, THESIS U HOUSTON HOU
[4]   DESIGN OF A COMBINED PHOTO-IONIZATION DETECTOR AND PHOTOIONIZATION-BASED ELECTRON-CAPTURE DETECTOR [J].
KAPILA, S ;
BORNHOP, DJ ;
MANAHAN, SE ;
NICKELL, GL .
JOURNAL OF CHROMATOGRAPHY, 1983, 259 (02) :205-210
[5]   ELECTRON AFFINITY SPECTROSCOPY - A NEW METHOD FOR THE IDENTIFICATION OF FUNCTIONAL GROUPS IN CHEMICAL COMPOUNDS SEPARATED BY GAS CHROMATOGRAPHY [J].
LOVELOCK, JE ;
LIPSKY, SR .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1960, 82 (02) :431-433
[6]  
NEUKERMANS A, 1982, J CHROMATOGR, V135, P1
[7]  
SIMMONDS PG, 1987, J CHROMATOGR, V399, P149
[8]   NON-RADIOACTIVE ELECTRON-CAPTURE DETECTOR FOR GAS-CHROMATOGRAPHY [J].
WENTWORTH, WE ;
LIMERO, T ;
BATTEN, CF ;
CHEN, ECM .
JOURNAL OF CHROMATOGRAPHY, 1989, 468 :215-224
[9]   ENVIRONMENTAL APPLICATIONS OF THE PULSED-DISCHARGE ELECTRON-CAPTURE DETECTOR [J].
WENTWORTH, WE ;
DSA, ED ;
CAI, HM ;
STEARNS, S .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1992, 30 (12) :478-485
[10]   PULSE-SAMPLING TECHNIQUE FOR STUDY OF ELECTRON-ATTACHMENT PHENOMENA [J].
WENTWORTH, WE ;
CHEN, E ;
LOVELOCK, JE .
JOURNAL OF PHYSICAL CHEMISTRY, 1966, 70 (02) :445-+