Comparison of two- and three-dimensional ultrasonography in lung volume measurement of normal fetuses

被引:15
作者
Araujo, Edward, Jr. [1 ]
Machado Nardozza, Luciano Marcondes [1 ]
Pires, Claudio Rodrigues [1 ]
Guimaraes Filho, Helio Antonio [1 ]
Moron, Antonio Fernandes [1 ]
机构
[1] Univ Fed Sao Paulo, Dept Obstet, BR-04023062 Sao Paulo, Brazil
关键词
fetus; lung volume measurements; three-dimensional image; ultrasound;
D O I
10.1515/JPM.2007.073
中图分类号
R71 [妇产科学];
学科分类号
100211 [妇产科学];
摘要
Aim: The purpose of this study was to compare the two-and three-dimensional methods for measuring fetal lung volume of normal fetuses. Methods: A cross-sectional study was performed with 51 normal pregnant women between 20 and 35 weeks. The ellipsoid formula (X*Y*Z*0.52) was used for volume calculation with the two-dimensional (2D) method. With the VOCAL (TM) (Virtual Organ Computer-aided Analysis) method, a rotation angle of 30 degrees was used. Intraclass correlation coefficient (ICC), paired Student's t-test. and Bland-Altman plots were used to compare the techniques. To calculate the intraobserver variability we used the ICC and compared the means between the two measures using the paired Student's p-test. Results: VOCAL (TM) and 2D methods were highly correlated (ICC = 0.919, and 0.873 for the right and left lungs, respectively), however, there was a disagreement. The fetal lung volume means calculated by the 2D method were always overestimated in relation to the means obtained by the VOCAL (TM), for the right lung (24.02 mL x 19.15 mL; P < 0.001), as well as for the left (16.03 mL x 13.77 mL; P = 0.002). As for the intraobserver variability, a good reproducibility was observed for the volume measurement of the left lung by the 2D technique (mean=0.40 mL.; P=0.57) and by the VOCAL (TM) (mean= -0.22 mL; P=0.63). The 2D method, however, presented low reproducibility for the right lung (mean = 1.73 mL; P = 0.31). Conclusion: The two-dimensional method had low agreement and low reproducibility in relation to the threedimensional method for measurement of fetal lung volume in normal fetuses.
引用
收藏
页码:415 / 421
页数:7
相关论文
共 30 条
[1]
A United States national reference for fetal growth [J].
Alexander, GR ;
Himes, JH ;
Kaufman, RB ;
Mor, J ;
Kogan, M .
OBSTETRICS AND GYNECOLOGY, 1996, 87 (02) :163-168
[2]
PULMONARY HYPOPLASIA - LUNG WEIGHT AND RADIAL ALVEOLAR COUNT AS CRITERIA OF DIAGNOSIS [J].
ASKENAZI, SS ;
PERLMAN, M .
ARCHIVES OF DISEASE IN CHILDHOOD, 1979, 54 (08) :614-618
[3]
Serial fetal lung volume measurement using three-dimensional ultrasound [J].
Bahmaie, A ;
Hughes, SW ;
Clark, T ;
Milner, A ;
Saunders, J ;
Tilling, K ;
Maxwell, DJ .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2000, 16 (02) :154-158
[4]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]
Assessment of fetal cerebellar volume using three-dimensional ultrasound [J].
Chang, CH ;
Chang, FM ;
Yu, CH ;
Ko, HC ;
Chen, HY .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (06) :981-988
[6]
Volumetric assessment of normal fetal lungs using three-dimensional ultrasound [J].
Chang, CH ;
Yu, CH ;
Chang, FM ;
Ko, HC ;
Chen, HY .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (07) :935-942
[7]
Three-dimensional ultrasound assessment of fetal liver volume in normal pregnancy: A comparison of reproducibility with two-dimensional ultrasound and a search for a volume constant [J].
Chang, FM ;
Hsu, KF ;
Ko, HC ;
Yao, BL ;
Chang, CH ;
Yu, CH ;
Chen, HY .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (03) :381-389
[8]
Fetal heart volume assessment by three-dimensional ultrasound [J].
Chang, FM ;
Hsu, KF ;
Ko, HC ;
Yao, BL ;
Chang, CH ;
Yu, CH ;
Liang, TI ;
Chen, HY .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1997, 9 (01) :42-48
[9]
SERIAL THORACIC VERSUS ABDOMINAL CIRCUMFERENCE RATIOS FOR THE PREDICTION OF PULMONARY HYPOPLASIA IN PREMATURE RUPTURE OF THE MEMBRANES REMOTE FROM TERM [J].
DALTON, M ;
MERCER, B ;
RIDDICK, E ;
DUDLEY, D .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1992, 166 (02) :658-663
[10]
Reliability of prenatal sonographic lung biometry in the diagnosis of pulmonary hypoplasia [J].
Heling, KS ;
Tennstedt, C ;
Chaoui, R ;
Kalache, KD ;
Hartung, J ;
Bollmann, R .
PRENATAL DIAGNOSIS, 2001, 21 (08) :649-657