Comparison of the performance of a forced-air and a radiant floor residential heating system connected to solar collectors

被引:6
作者
Haddad, Kammel [1 ]
Purdy, Julia
Laouadi, Aziz
机构
[1] CANMET Energy Technol Ctr, Ottawa, ON K1A 0E4, Canada
[2] Natl Res Council Canada, Ottawa, ON K1A 0R6, Canada
来源
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME | 2007年 / 129卷 / 04期
关键词
forced-air system; radiant floor system; solar collector; simulation models;
D O I
10.1115/1.2770754
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A detailed building energy analysis tool is used to model the performance of a forced-air system and a radiant floor system. These two systems use a low-temperature tank to store solar energy from a solar collector array. An electrically heated tank at a higher temperature is used to provide any additional heat needed to meet the space heating load. The simulation models developed are then used to compare the performance of the,forced-air and radiant floor systems based on maintaining the same operative temperature inside the space. It is found that the portion of the heating load that comes from solar energy is higher in the case of the radiant system. This portion from solar energy increases even further when the operating temperature of the radiant floor is lowered. The results also show that the energy performance of the radiant floor relative to the forced-air system improves for houses with higher envelope R-values and infiltration rates. Given the many different interacting factors that influence the performance of the solar-assisted systems studied, it is very important to use detailed simulation models to help assess which system is more energy efficient for a particular application.
引用
收藏
页码:465 / 472
页数:8
相关论文
共 10 条
[1]  
ATAER AE, 1994, P ASME INT ABS HEAT, P385
[2]  
Duffie JA., 1980, Solar engineering of thermal processes
[3]  
*ESRU, 2002, ESP R SYST BUILD EN, V10
[4]  
HADDAD KH, 2001, ASHRAE T, P713
[5]  
KILKIS BI, 1993, ASHRAE TRAN, V99, P521
[6]   Development of a radiant heating and cooling model for building energy simulation software [J].
Laouadi, A .
BUILDING AND ENVIRONMENT, 2004, 39 (04) :421-431
[7]  
LAOUADI A, 2002, B32131 NAT RES COUNC
[8]  
Olesen BW, 2002, ASHRAE J, V44, P19
[9]  
Tsilingiris P. T., 1991, Renewable Energy, V1, P13, DOI 10.1016/0960-1481(91)90097-9
[10]   AN INVESTIGATION OF A RESIDENTIAL SOLAR-SYSTEM COUPLED TO A RADIANT PANEL CEILING [J].
ZHANG, Z ;
PATE, M ;
NELSON, R .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1988, 110 (03) :172-179