Surface analysis of Ti-15Zr-4Nb-4Ta alloy after implantation in rat tibia

被引:91
作者
Okazaki, Y
Nishimura, E
Nakada, H
Kobayashi, K
机构
[1] Minist Int Trade & Ind, Agcy Ind Sci & Technol, Mech Engn Lab, Tsukuba, Ibaraki 3058564, Japan
[2] Minist Int Trade & Ind, Agcy Ind Sci & Technol, Japanese Ind Stand Ctr, Tsukuba, Ibaraki 3050044, Japan
[3] Nihon Univ Dent Matsudo, Chiba 2718587, Japan
关键词
Ti alloy; rat tibia implantation; new bone formation; surface analysis; metal concentrations in dried bone tissue; released metallic ions;
D O I
10.1016/S0142-9612(00)00221-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
A new Ti-15Zr-4Nb-4Ta alloy without V was implanted in rat tibiae for 6-48 weeks. The new bone formation surrounding the Ti implant in bone marrow, surface analysis of the Ti alloy after implantation. and metal concentrations in dried bone tissue containing new bone were investigated. New bone was well Formed around the Ti-15Zr-4Nb-4Ta alloy implanted in bone marrow. The mean thickness of the new bone increased up to 24 weeks after implantation, and changes in the mean thickness thereafter, up to 48 weeks, were very small. The number of corrosion pits observed in the Ti-6Al-4V extra low interstitial (ELI) alloy surface tended to be slightly more than that of the Ti-15Zr-4Nb-4Ta alloy implant. The concentrations of metal elements in the bone tissue containing the new bone tended to increase slightly more than in bents without the implant. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:599 / 607
页数:9
相关论文
共 20 条
[1]
METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS [J].
AGINS, HJ ;
ALCOCK, NW ;
BANSAL, M ;
SALVATI, EA ;
WILSON, PD ;
PELLICCI, PM ;
BULLOUGH, PG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :347-356
[2]
SERUM CONCENTRATIONS OF CHROMIUM, COBALT AND NICKEL AFTER TOTAL HIP-REPLACEMENT - A 6 MONTH STUDY [J].
BLACK, J ;
MAITIN, EC ;
GELMAN, H ;
MORRIS, DM .
BIOMATERIALS, 1983, 4 (03) :160-164
[3]
METAL-ION RELEASE AFTER TOTAL HIP-REPLACEMENT [J].
DOBBS, HS ;
MINSKI, MJ .
BIOMATERIALS, 1980, 1 (04) :193-198
[4]
CHARACTERISTICS OF TRACE IONS RELEASED FROM EMBEDDED METAL IMPLANTS IN THE RABBIT [J].
FERGUSON, AB ;
AKAHOSHI, Y ;
LAING, PG ;
HODGE, ES .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1962, 44 (02) :323-336
[5]
THE IONIZATION OF METAL IMPLANTS IN LIVING TISSUES [J].
FERGUSON, AB ;
LAING, PG ;
HODGE, ES .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1960, 42 (01) :77-90
[6]
THE DIFFERENCES IN TOXICITY AND RELEASE OF BONE-RESORBING MEDIATORS INDUCED BY TITANIUM AND COBALT-CHROMIUM-ALLOY WEAR PARTICLES [J].
HAYNES, DR ;
ROGERS, SD ;
HAY, S ;
PEARCY, MJ ;
HOWIE, DW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (06) :825-834
[7]
CEMENTLESS TOTAL HIP-REPLACEMENT - BIOACTIVE GLASS-CERAMIC COATING STUDIED IN DOGS [J].
IDO, K ;
MATSUDA, Y ;
YAMAMURO, T ;
OKUMURA, H ;
OKA, M ;
TAKAGI, H .
ACTA ORTHOPAEDICA SCANDINAVICA, 1993, 64 (06) :607-612
[8]
RELEASE AND EXCRETION OF METAL IN PATIENTS WHO HAVE A TOTAL HIP-REPLACEMENT COMPONENT MADE OF TITANIUM-BASE ALLOY [J].
JACOBS, JJ ;
SKIPOR, AK ;
BLACK, J ;
URBAN, RM ;
GALANTE, JO .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (10) :1475-1486
[9]
Kawahara H., 1963, J JAPANESE SOC DENT, V4, P65
[10]
In-vitro corrosion and wear of titanium alloys in the biological environment [J].
Khan, MA ;
Williams, RL ;
Williams, DF .