Analysis of microcontaminants in aqueous samples by fully automated on-line solid-phase extraction gas chromatography mass selective detection

被引:53
作者
Louter, AJH
vanBeekvelt, CA
Montanes, PC
Slobodnik, J
Vreuls, JJ
Brinkman, UAT
机构
关键词
water analysis; automation; environmental analysis; solid-phase extraction; sample preparation; pesticides;
D O I
10.1016/0021-9673(95)00979-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The trace-level analysis of unknown organic pollutants in water requires the use of fast and sensitive methods which also provide structural information. In the present study, an on-line technique was used which combines sample preparation by means of solid-phase extraction (SPE) on a small precolumn packed with a hydrophobic phase, and capillary gas chromatography (GC) with mass spectrometric (MS) detection. Sample preparation was carried out in a fully automated SPE module which was connected to the GC system via an on-column interface. The on-column interface was selected because of its wide application range. The mass spectrometer was preferably used in the full-scan acquisition mode because of the intended identification. The total system including the SPE module, was controlled by the MS software which allowed unattended analysis of a series of samples. The feasibility of on-line SPE-GC-MS was demonstrated by analysing a variety of surface water samples in order to detect and identify non-target compounds. With a sample volume of only 10 ml various micropollutants could be identified, and also quantified, at levels below 0.1 mu g/l. The system proved to be flexible, and the sample preparation could easily be adapted to analyse organochlorine pesticides by adding 30 vol.% of methanol to the raw sample. Samples were taken from several European (Aries, Greece; Ebro, Spain; Meuse, Netherlands; Nitra, Slovakia; Rhine, Germany; Thames, UK; Varta, Poland) and American (Sacramento, USA; Amazon, Brazil) rivers. An example of the identification of unknown microcontaminants in waste water is also presented, which is further evidence of the robustness and flexibility of the SPE-GC-MS analyzer.
引用
收藏
页码:67 / 83
页数:17
相关论文
共 25 条
[1]  
BARCELO D, 1991, ANALYST, V116, P682
[2]  
BULTERMAN AJ, 1993, HRC-J HIGH RES CHROM, V16, P397, DOI 10.1002/jhrc.1240160703
[3]   GRAPHITIZED CARBON-BLACK EXTRACTION CARTRIDGES FOR MONITORING POLAR PESTICIDES IN WATER [J].
DICORCIA, A ;
SAMPERI, R ;
MARCOMINI, A ;
STELLUTO, S .
ANALYTICAL CHEMISTRY, 1993, 65 (07) :907-912
[4]   COUPLING OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CAPILLARY GAS-CHROMATOGRAPHY [J].
GROB, K ;
FROHLICH, D ;
SCHILLING, B ;
NEUKOM, HP ;
NAGELI, P .
JOURNAL OF CHROMATOGRAPHY, 1984, 295 (01) :55-61
[5]  
GROB K, 1991, ON LINE COUPLED LC G
[6]   ONLINE COUPLING OF SOLID-PHASE EXTRACTION AND GAS-CHROMATOGRAPHY WITH ATOMIC-EMISSION DETECTION FOR ANALYSIS OF TRACE POLLUTANTS IN AQUEOUS SAMPLES [J].
HANKEMEIER, T ;
LOUTER, AJH ;
RINKEMA, FD ;
BRINKMAN, UAT .
CHROMATOGRAPHIA, 1995, 40 (3-4) :119-124
[8]  
HINSHAW JV, 1994, LC GC INT, V10, P560
[9]   SOLID-PHASE EXTRACTION OF PESTICIDES FROM WATER - POSSIBLE INTERFERENCES FROM DISSOLVED ORGANIC MATERIAL [J].
JOHNSON, WE ;
FENDINGER, NJ ;
PLIMMER, JR .
ANALYTICAL CHEMISTRY, 1991, 63 (15) :1510-1513
[10]   MASS-SPECTROMETRY IN ENVIRONMENTAL ORGANIC-ANALYSIS [J].
LEVSEN, K .
ORGANIC MASS SPECTROMETRY, 1988, 23 (05) :406-415