Development of a biosensor for monitoring of glycerol during alcoholic fermentation

被引:48
作者
Compagnone, D
Esti, M
Messia, MC
Peluso, E
Palleschi, G
机构
[1] Univ Roma Tor Vergata, Dipartimento Sci & Tecnol Chim, I-00133 Rome, Italy
[2] Univ Molise, DISTAAM, Campobasso, Italy
关键词
glycerol; wine; fermentation; amperometry; FIA;
D O I
10.1016/S0956-5663(98)00055-4
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A biosensor for the measurement of glycerol in FIA was constructed using covalently immobilized glycerokinase and glycerol-3-phosphate oxidase in conjunction with a Pt based hydrogen peroxide probe. Different immobilization strategies have been studied including random and asymmetric immobilization onto a polymeric support and immobilization onto two different membranes. The latter resulted in the best configuration for batch measurement. The most effective configuration for measurement in FIA was the immobilization of glycerokinase in a glass beads reactor coupled with glycerol-3-phosphate oxidase on a preactivated Immobilon AV membrane kept at the electrode surface. Using a 250-mu l injection loop, 3 mmol ATP(Mg (+) (2)) in 0.1 M berate buffer pH 8.5 and a flow rate of 0.5 ml/min, a linear response in the 2 x 10(-6)/10(-3) mol/l range and a detection limit of 5 x 10(-7) mol/l were obtained for glycerol. Lifetime of the glycerol-3-phosphate membrane was extended up to 1 month by storage in the working buffer containing 1% DEAE-dextran and 5% lactitol. More than 350 samples can be assayed with this system. The biosensor was used to monitor off-line glycerol production during alcoholic fermentations carried out at different pHs and temperatures. (C) 1998 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:875 / 880
页数:6
相关论文
共 18 条
  • [1] Flow-through spectrofluorimetric sensor for the determination of glycerol in wine
    Canizares, P
    deCastro, MDL
    [J]. ANALYST, 1995, 120 (12) : 2837 - 2840
  • [2] AMPEROMETRIC GLUTATHIONE ELECTRODES
    COMPAGNONE, D
    FEDERICI, G
    SCARCIGLIA, L
    PALLESCHI, G
    [J]. BIOSENSORS & BIOELECTRONICS, 1993, 8 (05) : 257 - 263
  • [3] GARDNER N, 1993, APPL ENVIRON MICROB, V59, P2022, DOI 10.1128/AEM.59.7.2022-2028.1993
  • [4] EXTENDED SHELF-LIFE OF ENZYME-BASED BIOSENSORS USING A NOVEL STABILIZATION SYSTEM
    GIBSON, TD
    HULBERT, JN
    PARKER, SM
    WOODWARD, JR
    HIGGINS, IJ
    [J]. BIOSENSORS & BIOELECTRONICS, 1992, 7 (10) : 701 - 708
  • [5] STABILIZATION OF ANALYTICAL ENZYMES USING A NOVEL POLYMER CARBOHYDRATE SYSTEM AND THE PRODUCTION OF A STABILIZED, SINGLE REAGENT FOR ALCOHOL ANALYSIS
    GIBSON, TD
    HIGGINS, IJ
    WOODWARD, JR
    [J]. ANALYST, 1992, 117 (08) : 1293 - 1297
  • [6] THE USE OF AN IMMOBILIZED GLYCEROL DEHYDROGENASE NYLON-TUBE REACTOR IN THE DETERMINATION OF GLYCEROL
    HINSCH, W
    SUNDARAM, PV
    [J]. CLINICA CHIMICA ACTA, 1980, 104 (01) : 87 - 94
  • [7] An enzymatic method for the determination of ATP and glycerol with an automated FIA system
    Kiranas, ER
    Karayannis, MI
    TzouwaraKarayanni, SM
    [J]. ANALYTICAL LETTERS, 1997, 30 (03) : 537 - 552
  • [8] ENZYME ELECTRODES WITH IMPROVED MECHANICAL AND ANALYTICAL CHARACTERISTICS OBTAINED BY BINDING ENZYMES TO NYLON NETS
    MASCINI, M
    IANNELLO, M
    PALLESCHI, G
    [J]. ANALYTICA CHIMICA ACTA, 1983, 146 (FEB) : 135 - 148
  • [9] MASCINI M, 1987, CLIN CHEM, V33, P591
  • [10] RELIABLE AMPEROMETRIC DETERMINATION OF GLYCEROL AND GLYCEROL-3-PHOSPHATE WITH A BIENZYMATIC NYLON MEMBRANE-ELECTRODE
    MERCHIE, B
    GIRARD, A
    MAISTERRENA, B
    MICHALON, P
    COUTURIER, R
    [J]. ANALYTICA CHIMICA ACTA, 1992, 263 (1-2) : 85 - 91