Blood-brain barrier and electromagnetic fields:: Effects of scopolamine methylbromide on working memory after whole-body exposure to 2.45 GHz microwaves in rats

被引:33
作者
Cosquer, B
de Vasconcelos, AP
Fröhlich, J
Cassel, JC
机构
[1] Univ Strasbourg, CNRS, UMR 7521, LN2C,Inst Federaratif Rech 37,GDR 2905, F-67000 Strasbourg, France
[2] ETH, IT IS Fdn, CH-8092 Zurich, Switzerland
关键词
blood-brain barrier; Evans blue; high frequency; microwaves; radial maze; scopolamine; spatial memory; working memory;
D O I
10.1016/j.bbr.2005.02.025
中图分类号
B84 [心理学]; C [社会科学总论]; Q98 [人类学];
学科分类号
03 ; 0303 ; 030303 ; 04 ; 0402 ;
摘要
We first verified that our 12-arm radial maze test enabled demonstration of memory deficits in rats treated with the muscarinic antagonist scopolamine hydrobromide (0.5 mg/kg, i.p.). We then investigated whether a systemically-injected quatemary-ammonium derivate of this antagonist (scopolamine methylbromide; MBR), which poorly crosses the blood-brain barrier (BBB), altered maze performance after a 45-min exposure to 2.45 GHz electromagnetic field (EMF; 2 mu s pulse width, 500 pps, whole-body specific energy absorption rate [SAR] of 2.0 W/kg, +/- 2 dB and brain averaged SAR of 3.0 W/kg, 3 dB); if observed, such an alteration would reflect changes in BBB permeability. The drug was injected before or after exposure. Controls were naive rats (no experience of the exposure device) and sham-exposed rats (experience of the exposure device without microwaves). In a final approach, rats were subjected to i.v. injections of Evans blue, a dye binding serum albumin, before or after EMF exposure. Whether scopolamine MBR was injected before or after exposure, the exposed rats did not perform differently from their naive or sham-exposed counterparts. Thus, EMFs most probably failed to disrupt the BBB. This conclusion was further supported by the absence of Evans blue extravasation into the brain parenchyma of our exposed rats. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:229 / 237
页数:9
相关论文
共 31 条
[1]  
[Anonymous], 1971, Statistical Principles in Experimental Design
[2]   DISTRIBUTION OF CD-109 IN THE NERVOUS-SYSTEM OF RATS AFTER INTRAVENOUS-INJECTION [J].
ARVIDSON, B ;
TJALVE, H .
ACTA NEUROPATHOLOGICA, 1986, 69 (1-2) :111-116
[3]  
ASANOV TP, 1966, IEEE POWER ENG SOC S, V10
[4]   Whole-body exposure to 2.45 GHz electromagnetic fields does not alter radial-maze performance in rats [J].
Cassel, JC ;
Cosquer, B ;
Galani, R ;
Kuster, N .
BEHAVIOURAL BRAIN RESEARCH, 2004, 155 (01) :37-43
[5]   SCOPOLAMINE TREATMENT AND FIMBRIA-FORNIX LESIONS - MIMETIC EFFECTS ON RADIAL MAZE PERFORMANCE [J].
CASSEL, JC ;
KELCHE, C .
PHYSIOLOGY & BEHAVIOR, 1989, 46 (03) :347-353
[6]  
CLASEN RA, 1970, J NEUROPATH EXP NEUR, V29, P266
[7]   Radial arm maze performance of rats following repeated low level microwave radiation exposure [J].
Cobb, BL ;
Jauchem, JR ;
Adair, ER .
BIOELECTROMAGNETICS, 2004, 25 (01) :49-57
[8]   Microwave effects on the nervous system [J].
D'Andrea, JA ;
Chou, CK ;
Johnston, SA ;
Adair, ER .
BIOELECTROMAGNETICS, 2003, :S107-S147
[9]  
Ebert U, 1998, EUR J CLIN INVEST, V28, P944
[10]   Effect of long-term mobile communication microwave exposure on vascular permeability in mouse brain [J].
Finnie, JW ;
Blumbergs, PC ;
Manavis, J ;
Utteridge, TD ;
Gebski, V ;
Davies, RA ;
Vernon-Roberts, B ;
Kuchel, TR .
PATHOLOGY, 2002, 34 (04) :344-347