Development of an improved methodology to detect infectious airborne influenza virus using the NIOSH bioaerosol sampler

被引:60
作者
Cao, G. [1 ]
Noti, J. D. [1 ]
Blachere, F. M. [1 ]
Lindsley, W. G. [1 ]
Beezhold, D. H. [1 ]
机构
[1] Ctr Dis Control & Prevent, Allergy & Clin Immunol Branch, Hlth Effects Lab Div, Natl Inst Occupat Safety & Hlth, Morgantown, WV 26505 USA
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2011年 / 13卷 / 12期
关键词
RELATIVE-HUMIDITY; TRANSMISSION; INACTIVATION;
D O I
10.1039/c1em10607d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A unique two-stage cyclone bioaerosol sampler has been developed at NIOSH that can separate aerosols into three size fractions. The ability of this sampler to collect infectious airborne viruses from a calm-air chamber loaded with influenza A virus was tested. The sampler's efficiency at collecting aerosolized viral particles from a calm-air chamber is essentially the same as that from the high performance SKC BioSampler that collects un-fractionated particles directly into a liquid media (2.4 x 10(4) total viral particles per liter of sampled air (TVP/L) versus 2.6 x 10(4) TVP/L, respectively, after 15 min) and the efficiency is relatively constant over collection times of 15, 30 and 60 min. Approximately 34% of the aerosolized infectious virus collected after 15 min with the NIOSH bioaerosol sampler remained infectious, and infectious virus was found in all three size fractions. After 60 min of sampling, the infectious virus/liter air found in the NIOSH bioaerosol sampler was 15% of that found in the SKC BioSampler. This preservation of infectivity by the NIOSH bioaerosol sampler was maintained even when the initial infectivity prior to aerosolization was as low as 0.06%. The utility of the NIOSH bioaerosol sampler was further extended by incorporating an enhanced infectivity detection methodology developed in our laboratory, the viral replication assay, which amplified the infectious virus making it more readily detectable.
引用
收藏
页码:3321 / 3328
页数:8
相关论文
共 26 条
[1]   Inactivation of viruses in bubbling processes utilized for personal bioaerosol monitoring [J].
Agranovski, IE ;
Safatov, AS ;
Borodulin, AI ;
Pyankov, OV ;
Petrishchenko, VA ;
Sergeev, AN ;
Agafonov, AP ;
Ignatiev, GM ;
Sergeev, AA ;
Agranovski, V .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2004, 70 (12) :6963-6967
[2]  
*AM C GOV IND HYG, DOC THRESH LIM VAL B
[3]   Enhanced detection of infectious airborne influenza virus [J].
Blachere, Francoise M. ;
Cao, Gang ;
Lindsley, William G. ;
Noti, John D. ;
Beezhold, Donald H. .
JOURNAL OF VIROLOGICAL METHODS, 2011, 176 (1-2) :120-124
[4]   Measurement of Airborne Influenza Virus in a Hospital Emergency Department [J].
Blachere, Francoise M. ;
Lindsley, William G. ;
Pearce, Terri A. ;
Anderson, Stacey E. ;
Fisher, Melanie ;
Khakoo, Rashida ;
Meade, Barbara J. ;
Lander, Owen ;
Davis, Stephen ;
Thewlis, Robert E. ;
Celik, Ismail ;
Chen, Bean T. ;
Beezhold, Donald H. .
CLINICAL INFECTIOUS DISEASES, 2009, 48 (04) :438-440
[5]   Bioaerosol sampling for the detection of aerosolized influenza virus [J].
Blachere, Francoise M. ;
Lindsley, William G. ;
Slaven, James E. ;
Green, Brett J. ;
Anderson, Stacey E. ;
Chen, Bean T. ;
Beezhold, Don H. .
INFLUENZA AND OTHER RESPIRATORY VIRUSES, 2007, 1 (03) :113-120
[6]   Detection of airborne severe acute respiratory syndrome (SARS) coronavirus and environmental contamination in SARS outbreak units [J].
Booth, TF ;
Kournikakis, B ;
Bastien, N ;
Ho, J ;
Kobasa, D ;
Stadnyk, L ;
Li, Y ;
Spence, M ;
Paton, S ;
Henry, B ;
Mederski, B ;
White, D ;
Low, DE ;
McGeer, A ;
Simor, A ;
Vearncombe, M ;
Downey, J ;
Jamieson, FB ;
Tang, P ;
Plummer, F .
JOURNAL OF INFECTIOUS DISEASES, 2005, 191 (09) :1472-1477
[7]   Defense against filoviruses used as biological weapons [J].
Bray, M .
ANTIVIRAL RESEARCH, 2003, 57 (1-2) :53-60
[8]   INACTIVATION OF SEMLIKI FOREST VIRUS IN AEROSOLS [J].
DEJONG, JC ;
HARMSEN, M ;
PLANTINGA, AD ;
TROUWBORST, T .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1976, 32 (03) :315-319
[9]   Airborne influenza virus detection with four aerosol samplers using molecular and infectivity assays: considerations for a new infectious virus aerosol sampler [J].
Fabian, P. ;
McDevitt, J. J. ;
Houseman, E. A. ;
Milton, D. K. .
INDOOR AIR, 2009, 19 (05) :433-441
[10]   Design and use of a settling chamber for sampler evaluation under calm-air conditions [J].
Feather, GA ;
Chen, BT .