Minimizing ventricular pacing to reduce atrial fibrillation in sinus-node disease

被引:355
作者
Sweeney, Michael O.
Bank, Alan J.
Nsah, Emmanuel
Koullick, Maria
Zeng, Qian Cathy
Hettrick, Douglas
Sheldon, Todd
Lamas, Gervasio A.
机构
[1] Brigham & Womens Hosp, Cardiac Arrhythmia Serv, Boston, MA 02115 USA
[2] St Paul Heart Clin, St Paul, MN USA
[3] Peninsula Cardiol Assoc, Salisbury, MD USA
[4] Medtronic, Minneapolis, MN USA
[5] Mt Sinai Med Ctr, Miami Beach, FL 33140 USA
关键词
D O I
10.1056/NEJMoa071880
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Conventional dual-chamber pacing maintains atrioventricular synchrony but results in high percentages of ventricular pacing, which causes ventricular desynchronization and has been linked to an increased risk of atrial fibrillation in patients with sinus-node disease. Methods We randomly assigned 1065 patients with sinus-node disease, intact atrioventricular conduction, and a normal QRS interval to receive conventional dual-chamber pacing (535 patients) or dual-chamber minimal ventricular pacing with the use of new pacemaker features designed to promote atrioventricular conduction, preserve ventricular conduction, and prevent ventricular desynchronization (530 patients). The primary end point was time to persistent atrial fibrillation. Results The mean (+/-SD) follow-up period was 1.7+/-1.0 years when the trial was stopped because it had met the primary end point. The median percentage of ventricular beats that were paced was lower in dual-chamber minimal ventricular pacing than in conventional dual-chamber pacing (9.1% vs. 99.0%, P<0.001), whereas the percentage of atrial beats that were paced was similar in the two groups (71.4% vs. 70.4%, P=0.96). Persistent atrial fibrillation developed in 110 patients, 68 (12.7%) in the group assigned to conventional dual-chamber pacing and 42 (7.9%) in the group assigned to dual-chamber minimal ventricular pacing. The hazard ratio for development of persistent atrial fibrillation in patients with dual-chamber minimal ventricular pacing as compared with those with conventional dual-chamber pacing was 0.60 (95% confidence interval, 0.41 to 0.88; P=0.009), indicating a 40% reduction in relative risk. The absolute reduction in risk was 4.8%. The mortality rate was similar in the two groups (4.9% in the group receiving dual-chamber minimal ventricular pacing vs. 5.4% in the group receiving conventional dual-chamber pacing, P=0.54). Conclusions Dual-chamber minimal ventricular pacing, as compared with conventional dual-chamber pacing, prevents ventricular desynchronization and moderately reduces the risk of persistent atrial fibrillation in patients with sinus-node disease.
引用
收藏
页码:1000 / 1008
页数:9
相关论文
共 37 条
[1]   Long-term follow-up of patients from a randomised trial of atrial versus ventricular pacing for sick-sinus syndrome [J].
Andersen, HR ;
Nielsen, JC ;
Thomsen, PEB ;
Thuesen, L ;
Mortensen, PT ;
Vesterlund, T ;
Pedersen, AK .
LANCET, 1997, 350 (9086) :1210-1216
[2]   Atrioventricular conduction during long-term follow-up of patients with sick sinus syndrome [J].
Andersen, HR ;
Nielsen, JC ;
Thomsen, PEB ;
Thuesen, L ;
Vesterlund, T ;
Pedersen, AK ;
Mortensen, PT .
CIRCULATION, 1998, 98 (13) :1315-1321
[3]   EFFECTS OF AN ACUTE INCREASE IN ATRIAL PRESSURE ON ATRIAL REFRACTORINESS IN HUMANS [J].
CALKINS, H ;
ELATASSI, R ;
KALBFLEISCH, S ;
LANGBERG, J ;
MORADY, F .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (11) :1674-1680
[4]   Effects of physiologic pacing versus ventricular pacing on the risk of stroke and death due to cardiovascular causes [J].
Connolly, SJ ;
Kerr, CR ;
Gent, M ;
Roberts, RS ;
Yusuf, S ;
Gillis, AM ;
Sami, MH ;
Talajic, M ;
Tang, ASL ;
Klein, GJ ;
Lau, C ;
Newman, DM .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (19) :1385-1391
[5]  
COX DR, 1972, J R STAT SOC B, V34, P187
[6]   ACC/AHA/ESC guidelines for the management of patients with atrial fibrillation:: Executive summary -: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines and Policy Conferences (Committee to Develop Guidelines for the Management of Patients with Atrial Fibrillation) [J].
Fuster, V ;
Rydén, LE ;
Asinger, RW ;
Cannom, DS ;
Crijns, HJ ;
Frye, RL ;
Halperin, JL ;
Kay, GN ;
Klein, WW ;
Lévy, S ;
McNamara, RL ;
Prystowsky, EN ;
Wann, LS ;
Wyse, DG ;
Gibbons, RJ ;
Antman, EM ;
Alpert, JS ;
Faxon, DP ;
Fuster, V ;
Gregoratos, G ;
Hiratzka, LF ;
Jacobs, AK ;
Russell, RO ;
Smith, SC ;
Klein, WW ;
Alonso-Garcia, A ;
Blomström-Lundqvist, C ;
De Backer, G ;
Flather, M ;
Hradec, J ;
Oto, A ;
Parkhomenko, A ;
Silber, S ;
Torbicki, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (04) :1231-1265
[7]   Atrial fibrillation after DDDR pacemaker implantation [J].
Gillis, AM ;
Morck, M .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (06) :542-547
[8]   Atrial high rate episodes detected by pacemaker diagnostics predict death and stroke - Report of the atrial diagnostics ancillary study of the MOde Selection Trial (MOST) [J].
Glotzer, TV ;
Hellkamp, AS ;
Zimmerman, J ;
Sweeney, MO ;
Yee, R ;
Marinchak, R ;
Cook, J ;
Paraschos, A ;
Love, J ;
Radoslovich, G ;
Lee, KL ;
Lamas, GA .
CIRCULATION, 2003, 107 (12) :1614-1619
[9]  
Gregoratos Gabriel, 2002, Circulation, V106, P2145, DOI 10.1161/01.CIR.0000035996.46455.09
[10]   Cardiovascular outcomes with atrial-based pacing compared with ventricular pacing - Meta-analysis of randomized trials, using individual patient data [J].
Healey, Jeffrey S. ;
Toff, William D. ;
Lamas, Gervasio A. ;
Andersen, Henning R. ;
Thorpe, Kevin E. ;
Ellenbogen, Kenneth A. ;
Lee, Kerry L. ;
Skene, Allan M. ;
Schron, Eleanor B. ;
Skehan, J. Douglas ;
Goldman, Lee ;
Roberts, Robin S. ;
Camm, A. John ;
Yusuf, Salim ;
Connolly, Stuart J. .
CIRCULATION, 2006, 114 (01) :11-17