Individually addressable gel-integrated voltammetric microelectrode array for high resolution measurement of concentration profiles at interfaces

被引:28
作者
Pei, JH
Tercier-Waeber, ML
Buffle, J
Fiaccabrino, GC
Koudelka-Hep, M
机构
[1] Univ Geneva, CABE, Dept Inorgan Analyt & Appl Chem Sci 2, CH-1211 Geneva 4, Switzerland
[2] Univ Neuchatel, Inst Microtechnol, CH-2007 Neuchatel, Switzerland
关键词
D O I
10.1021/ac000615e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The application of a novel voltammetric probe, based on an individually addressable gel-integrated microelectrode array (IA-GIME), for real-time, high-spatial resolution concentration profile measurements at interfaces is described. Reliability and validity of steep metal concentration gradients obtained with this novel system have been demonstrated by performing systematic tests,at-well-controlled liquid-liquid and liquid-solid interfaces. The Liquid-liquid interface was formed by two layers of aqueous solutions with different components; only one layer contained trace metal ions (Pb(II) and Cd(II)); the individually addressable microelectrode array was placed at the interface of the liquid-liquid system; the concentration profiles were recorded as function of time; and the effective diffusion coefficients were calculated. The liquid "solid" interface was formed from an aqueous solution layer overlying a bed of silica particles saturated with an aqueous solution. The sensor array has been used to monitor the diffusion processes of Tl(I) or Pb(II) from the liquid phase to the "solid" phase. The influences of porosity, geometry of the porous media, and complexation between metal ion and silica, on the diffusion processes, have been studied. All these results show that correct diffusion profiles of metal ions at interfaces can be obtained with 200-mum resolution with the IA-GIME, They also demonstrate that, for measurements in "solid" phase, the aforementioned factors must be considered carefully for correct calibration of any electrodes and the gel-integrated microelectrodes are unique tools to enable calibration of the sensors with synthetic solutions.
引用
收藏
页码:2273 / 2281
页数:9
相关论文
共 50 条
[1]   COMPLETE OXIDATION OF SOLID-PHASE SULFIDES BY MANGANESE AND BACTERIA IN ANOXIC MARINE-SEDIMENTS [J].
ALLER, RC ;
RUDE, PD .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1988, 52 (03) :751-765
[2]   MULTICHANNEL ELECTROCHEMICAL DETECTION WITH A MICROELECTRODE ARRAY IN FLOWING STREAMS [J].
AOKI, A ;
MATSUE, T ;
UCHIDA, I .
ANALYTICAL CHEMISTRY, 1992, 64 (01) :44-49
[3]   Gel-integrated microelectrode arrays for direct voltammetric measurements of heavy metals in natural waters and other complex media [J].
Belmont-Hébert, C ;
Tercier, ML ;
Buffle, J ;
Fiaccabrino, GC ;
de Rooij, NF ;
Koudelka-Hep, M .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2949-2956
[4]   INSITU COLLECTION OF DIAGENETIC IRON AND MANGANESE OXYHYDROXIDES FROM NATURAL SEDIMENTS [J].
BELZILE, N ;
DEVITRE, RR ;
TESSIER, A .
NATURE, 1989, 340 (6232) :376-377
[5]   DIFFUSION OF SEA-WATER IONS .1. DIFFUSION OF SEA-WATER INTO A DILUTE-SOLUTION [J].
BENYAAKOV, S .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1972, 36 (12) :1395-+
[6]   DEVELOPMENT OF A GOLD AMALGAM VOLTAMMETRIC MICROELECTRODE FOR THE DETERMINATION OF DISSOLVED FE, MN, O-2, AND S(-II) IN POREWATERS OF MARINE AND FRESH-WATER SEDIMENTS [J].
BRENDEL, PJ ;
LUTHER, GW .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1995, 29 (03) :751-761
[7]   MICROELECTRONIC AND NANOELECTRONIC INTERFACING TECHNIQUES FOR BIOLOGICAL-SYSTEMS [J].
CONNOLLY, P ;
MOORES, GR ;
MONAGHAN, W ;
SHEN, J ;
BRITLAND, S ;
CLARK, P .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 6 (1-3) :113-121
[8]  
Crank J, 1979, MATH DIFFUSION
[9]  
DAVID RL, 1994, HDB CHEM PHYSICS, P5
[10]   PERFORMANCE-CHARACTERISTICS OF GEL PROBES USED FOR MEASURING THE CHEMISTRY OF PORE WATERS [J].
DAVISON, W ;
ZHANG, H ;
GRIME, GW .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1994, 28 (09) :1623-1632