A new polymethylmethacrylate membrane for hemodialysis

被引:40
作者
Bonomini, M [1 ]
Fiederling, B [1 ]
Bucciarelli, T [1 ]
Manfrini, V [1 ]
Diilio, C [1 ]
Albertazzi, A [1 ]
机构
[1] G ANNUNZIO UNIV,INST NEPHROL,CHIETI,ITALY
关键词
high performance liquid chromatography; polymethylmethacrylate membrane; Beta(2)-microglobulin; high molecular weight solutes; hemodialysis;
D O I
10.1177/039139889601900405
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
High molecular weight (MW) solutes are not removed during conventional hemodialysis (HD), and their accumulation is thought to play a role in some long-term HD complications (anemia, bone and joint pain, neuropathy, itching). The present trial was conducted to evaluate the removal capacity during in vivo HD of a new polymethylmethacrylate (PMMA) membrane (Filtryzer BK-F, 1.3 m(2)) compared to conventional PMMA (BK-P, 1.6 m(2)) and to cellulose acetate (CA, 1.3 m(2)). BK-F dialyzers, with a pore size of 100 A degrees and 62% porosity, are designed to remove high MW substances. Ten stable anuric RDT patients (53 +/- 13 years) were treated for one week with each membrane in a randomized sequence. Plasma concentrations of creatinine, BUN and beta(2)-microglobulin (beta(2)-M) were measured before (b) and after (a) HD to determine the reduction rate for these substances (%). Beta(2)-M concentration after HD was corrected for changes in distribution volume. Samples of spent dialysate were collected after 3 minutes, 120 minutes and at the end of HD sessions, and appropriately treated and concentrated for HPLC analysis. The reduction rate for BUN and creatinine was similar for the 3 membranes. BK-F showed a higher beta(2)-M reduction rate than BK-P (p<0.005) or CA (p<0.0001). HPLC analysis of dialysate showed prevalent peaks < 4 kilodaltons (kDa) throughout HD for BK-P and CA. Solutes > 10 kDa were infrequently detected. Peak profile during HD with BK-F was quite different, showing a predominant peak > 50 kDa which also included albumin. However, albumin loss significantly decreased after 120 minutes and at the end of dialysis compared with the 3-minute values, and was lower than that reported in CAPD patients. With BK-F a peak of MW > 500 kDa was also detected which previous studies indicated as a range characterized by the presence of erythropoiesis inhibitors. Use of the BK-F membrane in HD could afford satisfactory removal of high MW substances, thereby preventing or controlling some long-term HD complications such as anemia or beta(2)-M amyloid formation.
引用
收藏
页码:232 / 239
页数:8
相关论文
共 32 条
  • [1] ARAKAWA M, 1991, NEPHROL DIAL TRANS S, V2, P69
  • [2] BERGSTROM J, 1987, LANCET, V1, P628
  • [3] Bosch T, 1985, Contrib Nephrol, V46, P14
  • [4] CASEY TT, 1985, HUM PATHOL, V17, P731
  • [5] COSTIGAN MG, 1995, NEPHROL DIAL TRANSPL, V10, P648
  • [6] DAUGIRDAS JT, 1989, INT J ARTIF ORGANS, V12, P420
  • [7] GEIYO F, 1985, BIOCHEM BIOPH RES CO, V129, P701
  • [8] POLYMERIZATION OF INTACT BETA-2-MICROGLOBULIN IN TISSUE CAUSES AMYLOIDOSIS IN PATIENTS ON CHRONIC-HEMODIALYSIS
    GOREVIC, PD
    MUNOZ, PC
    CASEY, TT
    DIRAIMONDO, CR
    STONE, WJ
    PRELLI, FC
    RODRIGUES, MM
    POULIK, MD
    FRANGIONE, B
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1986, 83 (20) : 7908 - 7912
  • [9] HAAGWEBER M, 1994, NEPHROL DIAL TRANSPL, V9, P346
  • [10] BIOCOMPATIBILITY OF DIALYSIS MEMBRANES - EFFECTS OF CHRONIC COMPLEMENT ACTIVATION
    HAKIM, RM
    FEARON, DT
    LAZARUS, JM
    [J]. KIDNEY INTERNATIONAL, 1984, 26 (02) : 194 - 200