A sensitive flow analysis system for the fluorimetric determination of low levels of formaldehyde in alcoholic beverages

被引:55
作者
de Oliveira, Fabio Santos [1 ]
Sousa, Eliane Teixeira [1 ]
de Andrade, Jailson B. [1 ]
机构
[1] Univ Fed Bahia, Inst Quim, BR-40170 Salvador, BA, Brazil
关键词
formaldehyde determination; alcoholic beverages; fluoral-P; box-behnken design;
D O I
10.1016/j.talanta.2007.04.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive FIA method was developed for the selective determination of formaldehyde in alcoholic beverages. This method is based on the reaction of Fluoral-P (4-amine-3-pentene-2-one) with formaldehyde, leading to the formation of 3,5-diacetyl-1,4-dihydrolutidine (DDL), which fluoresces at lambda(ex) = 410 nm and lambda(em) = 510 nm. The analytical parameters were optimized by the response surface method using the Box-Behnken design. The proposed flow injection system allowed for the determination of up to 3.33 x 10(-5) mol L-1 of formaldehyde with R.S.D. < 2.5% and a detection limit of 3.1 ng mL(-1). The method was successfully applied to determine formaldehyde in alcoholic beverages, without requiring any sample pretreatment, and the results agreed with the reference at a 95% confidence level by paired t-test. In the optimized condition, the FIA system proved able to analyze up to 60 samples/h. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:561 / 566
页数:6
相关论文
共 46 条
[1]   Kinetic spectrophotometric determination of acetaldehyde [J].
Afkhami, A ;
Parham, H ;
Rezaei, M .
ANALYTICAL LETTERS, 2000, 33 (03) :527-538
[2]   Sensitive spectrophotometric determination of formaldehyde by inhibition of the malachite green-sulfite reaction [J].
Afkhami, A ;
Rezaei, M .
MICROCHEMICAL JOURNAL, 1999, 63 (02) :243-249
[3]   DETERMINATION OF ACETALDEHYDE BY FLOW-INJECTION ANALYSIS WITH SOLUBLE OR IMMOBILIZED ALDEHYDE DEHYDROGENASE [J].
ALMUAIBED, AM ;
TOWNSHEND, A .
ANALYTICA CHIMICA ACTA, 1987, 198 :37-44
[4]   Atmospheric carbonyl compounds: Sources, reactivity, concentration levels and toxicologic effects [J].
de Andrade, MVAS ;
Pinheiro, HLC ;
Pereira, PAD ;
de Andrade, JB .
QUIMICA NOVA, 2002, 25 (6B) :1117-1131
[5]   Analysis of low molecular mass phenolic compounds, furfural and 5-hydroxymethylfurfural in Brandy de Jerez by high-performance liquid chromatography diode array detection with direct injection [J].
Barroso, CG ;
Rodriguez, MC ;
Guillen, DA ;
PerezBustamante, JA .
JOURNAL OF CHROMATOGRAPHY A, 1996, 724 (1-2) :125-129
[6]   Authentication of tequila by gas chromatography and stable isotope ratio analyses [J].
Bauer-Christoph, C ;
Christoph, N ;
Aguilar-Cisneros, BO ;
López, MG ;
Richling, E ;
Rossmann, A ;
Schreier, P .
EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2003, 217 (05) :438-443
[7]   FLUORIMETRIC DETERMINATION OF FORMALDEHYDE [J].
BELMAN, S .
ANALYTICA CHIMICA ACTA, 1963, 29 (02) :120-&
[8]   Optimizing analytical methods using sequential response surface methodology.: Application to the pararosaniline determination of formaldehyde [J].
Bosque-Sendra, JM ;
Pescarolo, S ;
Cuadros-Rodríguez, L ;
García-Campaña, AM ;
Almansa-López, EM .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 369 (7-8) :715-718
[9]   High-performance liquid chromatography method for analysis of phenolic acids, phenolic aldehydes, and furanic derivatives in brandies. Development and validation [J].
Canas, S ;
Belchior, AP ;
Spranger, MI ;
Bruno-de-Sousa, R .
JOURNAL OF SEPARATION SCIENCE, 2003, 26 (6-7) :496-502
[10]   FLUORAL-P, A MEMBER OF A SELECTIVE FAMILY OF REAGENTS FOR ALDEHYDES [J].
COMPTON, BJ ;
PURDY, WC .
ANALYTICA CHIMICA ACTA, 1980, 119 (02) :349-357