A review of 356 Kinemax (Howmedica, Inc, Rutherford, NJ) cemented posterior cruciate ligament-retaining condylar total knee arthroplasties employing a symmetrical femoral component articulating with a medially offset symmetrical dome patella component was carried out to examine the results and determine the incidence and nature of the patellofemoral complications. Follow-up was from 3 to 8 years, with a mean of 5.1 years. A review of patellofemoral complications in previously reported homogeneous series of symmetrical and asymmetrical implants is presented. Mean postoperative I(nee Society scores improved to 91, function scores to 86, and Hospital of Special Surgery scores to 90 yielding 95% good and excellent results. Mean postoperative range of motion was - 1.5 degrees extension to 113 degrees flexion. There were five patellofemoral complications (1.4%), including two symptomatic subluxations, two distal pole avulsion fractures, and one lateral facet fracture. There were two reoperations necessary for patellofemoral problems (0.56%), one to correct subluxation and one for excision of the fractured lateral facet. These rates are lower than those previously reported for asymmetrical implants as well as current and phased-out symmetrical designs of total knee arthroplasty in the intermediate term. This review suggests that cemented total knee arthroplasty with symmetrical patellofemoral resurfacing with an offset patella dome and posterior cruciate ligament retention yields low patellofemoral complications and reoperations. The symmetrical femoral component appears to be a satisfactory compromise of "normal" femoral anatomy which decreases inventory and cost without adversely affecting patellofemoral function and complications.
引用
收藏
页码:753 / 762
页数:10
相关论文
共 52 条
[1]  
Aglietti P, 1988, J Arthroplasty, V3, P17, DOI 10.1016/S0883-5403(88)80049-4
[2]  
ANDRIACCI TP, 1995, HARV MED SCH CME COU
[3]   FAILURE OF THE METAL-BACKED PATELLAR COMPONENT AFTER TOTAL KNEE REPLACEMENT [J].
BAYLEY, JC ;
SCOTT, RD ;
EWALD, FC ;
HOLMES, GB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (05) :668-674
[4]  
BEIGHT JL, 1994, CLIN ORTHOP RELAT R, P139
[5]  
BERRY DJ, 1993, CLIN ORTHOP RELAT R, P110
[6]  
BOURNE RB, 1995, CLIN ORTHOP RELAT R, P156
[7]   LONG-TERM COMPLICATIONS AFTER TOTAL KNEE ARTHROPLASTY WITH OR WITHOUT RESURFACING OF THE PATELLA [J].
BOYD, AD ;
EWALD, FC ;
THOMAS, WH ;
POSS, R ;
SLEDGE, CB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (05) :674-681
[8]  
BRICK GW, 1988, CLIN ORTHOP RELAT R, P163
[9]  
COBB AC, 1990, J BONE JOINT SURG BR, V72, P532
[10]  
COLLIER JP, 1991, CLIN ORTHOP RELAT R, P198