Impact of hemodialysis on dual X-ray absorptiometry, bioelectrical impedance measurements, and anthropometry

被引:94
作者
Abrahamsen, B [1 ]
Hansen, TB [1 ]
Hogsberg, IM [1 ]
Pedersen, FB [1 ]
BeckNielsen, H [1 ]
机构
[1] ODENSE UNIV HOSP, DEPT NEPHROL, DK-5000 ODENSE C, DENMARK
关键词
hemodialysis; body composition; densitometry; dual X-ray absorptiometry; bioimpedance analysis; lean body mass; bone density;
D O I
10.1093/ajcn/63.1.80
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Dual X-ray absorptiometry (DXA) performs noninvasive assessment of bone and soft tissue with high precision. However, soft tissue algorithms assume that 73.2% of the lean body mass is water, a potential source of error in fluid retention. We evaluated DXA (model QDR-2000; Hologic Inc, Waltham, MA), bioelectrical impedance analysis (BLA), and simple anthropometry in 19 patients (9 women and 10 men, mean age 46 y) before and after hemodialysis, removing 0.9-4.3 L ((x) over bar: 2.8 L) of ultrafiltrate. The reduction in fat-free mass (FFM) measured by DXA was highly correlated with the ultrafiltrate, as determined by the reduction in gravimetric weight (r = 0.975, P < 0.0001; SEE: 233 g), whereas BLA was considerably less accurate in assessing FFM reductions (r = 0.66, P < 0.01; SEE: 757 g). Lumbar bone mineral density (BMD) was unaffected by dialysis, as were whole-body fat and BMD. Whole-body bone mineral content, however, was estimated to be 0.6% lower after dialysis. None of the simple anthropometric measurements correlated significantly with the reduction in FFM. In an unmodified clinical setting, DXA appears to be superior to other simple noninvasive methods for determining body composition, particularly when the emphasis is on repeated measurements.
引用
收藏
页码:80 / 86
页数:7
相关论文
共 28 条
  • [1] ELECTRICAL-IMPEDANCE IN ASSESSING HUMAN-BODY COMPOSITION - THE BIA METHOD
    ABUKHALED, M
    MCCUTCHEON, MJ
    REDDY, S
    PEARMAN, PL
    HUNTER, GR
    WEINSIER, RL
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1988, 47 (05) : 789 - 792
  • [2] DUAL X-RAY ABSORPTIOMETRY - A COMPARISON BETWEEN FAN-BEAM AND PENCIL BEAM SCANS
    BLAKE, GM
    PARKER, JC
    BUXTON, FMA
    FOGELMAN, I
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (790) : 902 - 906
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] BODY-COMPOSITION - PREDICTION OF NORMAL BODY POTASSIUM, BODY-WATER AND BODY-FAT IN ADULTS ON THE BASIS OF BODY HEIGHT, BODY-WEIGHT AND AGE
    BRUCE, A
    ANDERSSON, M
    ARVIDSSON, B
    ISAKSSON, B
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1980, 40 (05) : 461 - 473
  • [5] BRUMMER RJM, 1992, EUR J CLIN NUTR, V46, P47
  • [6] Cameron N., 1978, HUMAN GROWTH, DOI [10.1007/978-1-4684-2622-9_3, DOI 10.1007/978-1-4684-2622-9_3]
  • [7] IS BIOIMPEDANCE A GOOD PREDICTOR OF BODY-COMPOSITION CHANGE
    FORBES, GB
    SIMON, W
    AMATRUDA, JM
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1992, 56 (01) : 4 - 6
  • [8] BODY-COMPOSITION FOLLOWING HEMODIALYSIS - STUDIES USING DUAL-ENERGY X-RAY ABSORPTIOMETRY AND BIOELECTRICAL-IMPEDANCE ANALYSIS
    FORMICA, C
    ATKINSON, MG
    NYULASI, I
    MCKAY, J
    HEALE, W
    SEEMAN, E
    [J]. OSTEOPOROSIS INTERNATIONAL, 1993, 3 (04) : 192 - 197
  • [9] DETECTION OF SMALL CHANGES IN BODY-COMPOSITION BY DUAL-ENERGY X-RAY ABSORPTIOMETRY
    GOING, SB
    MASSETT, MP
    HALL, MC
    BARE, LA
    ROOT, PA
    WILLIAMS, DP
    LOHMAN, TG
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 57 (06) : 845 - 850
  • [10] INFLUENCE OF FAT ON BONE MEASUREMENTS WITH DUAL-ENERGY ABSORPTIOMETRY
    HANGARTNER, TN
    JOHNSTON, CC
    [J]. BONE AND MINERAL, 1990, 9 (01): : 71 - 81