Validity of double-layer charge-corrected voltammetry for assaying carbon monoxide coverages on ordered transition metals: comparisons with adlayer structures in electrochemical and ultrahigh vacuum environments

被引:148
作者
Gomez, R
Feliu, JM
Aldaz, A
Weaver, MJ [1 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
[2] Univ Alacant, Dept Quim Fis, E-03080 Alicante, Spain
基金
美国国家科学基金会;
关键词
carbon monoxide; chemisorption; electrochemical methods; infrared absorption spectroscopy; iridium; low-index single-crystal surfaces; metal-electrolyte interfaces; platinum; rhodium;
D O I
10.1016/S0039-6028(98)00295-7
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A coulometric procedure enabling the reliable and accurate evaluation of saturated CO coverages, theta(CO)(sat), on Pt-group transition-metal electrodes is outlined, and applied to CO adlayers on ordered low-index platinum, rhodium, and iridium surfaces in acidic aqueous media. Along with voltammetric data, the method utilizes previously described measurements of the charge displaced upon CO adsorption. The reverse of this charge, Q(dis), together with the "background" charge Q(b) flowing between a suitable pair of electrode potentials in the absence of CO, constitutes the overall "double-layer" correction Q(dl) to the total voltammetric charge Q(tot) measured for the electrooxidation of adsorbed CO between the same potentials. Significantly, the Q(dis) as well as the Q(b) component of Q(dl) typically constitutes moderate or even large corrections to Q(tot), so that the deduced of theta(CO)(sat) values are noticeably (20-30%) smaller than some voltammetric-based estimates reported earlier. However, the revised coulometric theta(CO)(sat) values are in consistently good agreement with the corresponding coverages obtained by means of an infrared spectrophotometric procedure. These theta(CO)(sat) values are compared with adlayer structural information obtained recently from in situ scanning tunneling microscopy along with infrared spectroscopy, and also with structural data for corresponding adlayers in ultrahigh vacuum (UHV). In most cases, the electrochemical and UHV-based theta(CO)(sat) values are not greatly different (within 5-10%), even though the CO binding site arrangements are often dissimilar in these two environments. The role of the electrode potential in affecting theta(CO)(sat) under some conditions via alterations in binding-site energetics, however, is noted for the Pt(111)/CO system. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:48 / 61
页数:14
相关论文
共 60 条