Towards image quality, beam energy and effective dose optimisation in digital thoracic radiography

被引:42
作者
Launders, JH
Cowen, AR
Bury, RF
Hawkridge, P
机构
[1] Gen Infirm, Dept Med Phys, Leeds LS1 3EX, W Yorkshire, England
[2] Gen Infirm, Dept Radiol, Leeds LS1 3EX, W Yorkshire, England
关键词
dose optimisation; digital radiography; image quality; radiation dose; radiation protection;
D O I
10.1007/s003300000525
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This paper outlines how objective measurements of both image quality, in terms of signal-to-noise ratio, and effective dose may be used as tools to find the optimum kVp range for a digital chest radiography system. Measurements were made with Thoravision, an amorphous selenium-based digital chest X-ray system. The entrance surface dose and the effective dose to an anthropomorphic chest phantom were determined demonstrating how effective dose is related to beam quality. The image quality was measured using detective quantum efficiency, threshold contrast and a radiologist preference trial involving 100 patients. The results show that, despite the fact that the entrance surface dose decreases as the kVp increases, the effective dose, a better measure of the risk, reaches a minimum value between 90 and 110 kVp; however, the image quality decreases as the kVp increases. In this study the optimum kVp for chest radiography, using a selenium-based radiography system, is in the range 90-110 kVp. This is contrary to the 120- to 150-kVp range that is commonly used. Also, this study shows how objective measurements can be used to optimise radiographic technique without prolonged patient trials.
引用
收藏
页码:870 / 875
页数:6
相关论文
共 23 条
[1]  
[Anonymous], 1991, ANN ICRP, V60
[2]  
BIRCH R, 1979, CATALOGUE SPECTRAL D
[3]   The Rose model, revisited [J].
Burgess, AE .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1999, 16 (03) :633-646
[4]   DIGITAL CHEST RADIOGRAPHY WITH PHOTOSTIMULABLE STORAGE PHOSPHORS - SIGNAL-TO-NOISE RATIO AS A FUNCTION OF KILOVOLTAGE WITH MATCHED EXPOSURE RISK [J].
CHOTAS, HG ;
FLOYD, CE ;
DOBBINS, JT ;
RAVIN, CE .
RADIOLOGY, 1993, 186 (02) :395-398
[5]  
*COUNC EUR COMM, 1996, 16260 EUR COUNC EUR
[6]   DIGITAL X-RAY-IMAGING [J].
COWEN, AR .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1991, 2 (08) :691-707
[7]   INVESTIGATION OF BASIC IMAGING PROPERTIES IN DIGITAL RADIOGRAPHY .2. NOISE WIENER SPECTRUM [J].
GIGER, ML ;
DOI, K ;
METZ, CE .
MEDICAL PHYSICS, 1984, 11 (06) :797-805
[8]  
HART D, 1994, NRPBR262
[9]  
HART D, 1996, NRPBR289
[10]  
HART D, 1995, NRPBSR262