Strategies for capillary electrophoresis:: Method development and validation for pharmaceutical and biological applications

被引:154
作者
Wätzig, H [1 ]
Degenhardt, M [1 ]
Kunkel, A [1 ]
机构
[1] Inst Pharm & Lebensmittelchem, D-97074 Wurzburg, Germany
关键词
capillary electrophoresis; method development; micellar electrokinetic capillary chromatography; validation; troubleshooting; review;
D O I
10.1002/elps.1150191603
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This review is in support of the development of selective, reproducible and validated capillary electrophoretis (CE) methods. Focusing on pharmaceutical and biological applications, the successful use of CE is demonstrated by more than 800 references, mainly from 1994 until 1998. Approximately 80 recent reviews have been catalogued. These articles sum up the existing strategies for method development in CE, especially in the search for generally accepted concepts, but also looking for new, promising reagents and ideas. General strategies for method development were derived not only with regard to selectivity and efficiency, but also with regard to precision, short analysis time, limit of detection, sample pretreatment requirements and validation. Standard buffer recipes, surfactants used in micellar electrokinetic capillary chromatography (MEKC), chiral selectors, useful buffer additives, polymeric separation media, electroosmotic flow (EOF) modifiers, dynamic and permanent coatings, actions to deal with complex matrices and aspects of validation are collected in 20 tables. Detailed schemes for the development of MEKC methods and chiral separations, for optimizing separation efficiency, means of troubleshooting, and other important information for key decisions during method development are given in 19 diagrams. Method development for peptide and protein separations, possibilities to influence the EOF and how to stabilize it, as well as indirect detection are considered in special sections.
引用
收藏
页码:2695 / 2752
页数:58
相关论文
共 805 条
[1]   RESOLUTION OF THE ENANTIOMERS OF OXAMNIQUINE BY CAPILLARY ELECTROPHORESIS AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CYCLODEXTRINS AND HEPARIN AS CHIRAL SELECTORS [J].
ABUSHOFFA, AM ;
CLARK, BJ .
JOURNAL OF CHROMATOGRAPHY A, 1995, 700 (1-2) :51-58
[2]  
ACKERMANS MT, 1992, J CHROMATOGR, V606, P229
[3]  
Albert M, 1997, J CHROMATOGR A, V757, P291, DOI 10.1016/S0021-9673(96)00782-0
[4]   SENSITIVITY ENHANCEMENT FOR CAPILLARY ELECTROPHORESIS [J].
ALBIN, M ;
GROSSMAN, PD ;
MORING, SE .
ANALYTICAL CHEMISTRY, 1993, 65 (10) :A489-A497
[5]   THE USE OF CAPILLARY ELECTROPHORESIS IN A MICROPREPARATIVE MODE - METHODS AND APPLICATIONS [J].
ALBIN, M ;
CHEN, SM ;
LOUIE, A ;
PAIRAUD, C ;
COLBURN, J ;
WIKTOROWICZ, J .
ANALYTICAL BIOCHEMISTRY, 1992, 206 (02) :382-388
[6]   FLUORESCENCE DETECTION IN CAPILLARY ELECTROPHORESIS - EVALUATION OF DERIVATIZING REAGENTS AND TECHNIQUES [J].
ALBIN, M ;
WEINBERGER, R ;
SAPP, E ;
MORING, S .
ANALYTICAL CHEMISTRY, 1991, 63 (05) :417-422
[7]   HIGH-SPEED DETERMINATION OF DRUG-RELATED IMPURITIES BY CAPILLARY ELECTROPHORESIS EMPLOYING COMMERCIAL INSTRUMENTATION [J].
ALTRIA, KD .
JOURNAL OF CHROMATOGRAPHY, 1993, 636 (01) :125-132
[8]   APPROACHES TO OPTIMIZATION OF PRECISION IN CAPILLARY ELECTROPHORESIS [J].
ALTRIA, KD ;
FABRE, H .
CHROMATOGRAPHIA, 1995, 40 (5-6) :313-320
[9]   HIGH AND LOW INJECTION VOLUMES IN CE FOR IMPROVED QUANTITATIVE-DETERMINATION OF DRUG-RELATED IMPURITIES [J].
ALTRIA, KD .
CHROMATOGRAPHIA, 1993, 35 (9-12) :493-496
[10]   CHIRAL SEPARATION OF BETA-AMINO ALCOHOLS BY CAPILLARY ELECTROPHORESIS USING CYCLODEXTRINS AS BUFFER ADDITIVES .1. EFFECT OF VARYING OPERATING PARAMETERS [J].
ALTRIA, KD ;
GOODALL, DM ;
ROGAN, MM .
CHROMATOGRAPHIA, 1992, 34 (1-2) :19-24