Sensitivity of model predictions of muscle function to changes in moment arms and muscle-tendon properties: A Monte-Carlo analysis

被引:136
作者
Ackland, David C. [1 ]
Lin, Yi-Chung [1 ]
Pandy, Marcus G. [1 ]
机构
[1] Univ Melbourne, Dept Mech Engn, Parkville, Vic 3010, Australia
基金
澳大利亚研究理事会;
关键词
Subject-specific model; Muscle model; Tendon slack length; Optimum muscle-fiber length; Peak isometric muscle force; NORMAL WALKING; MUSCULOSKELETAL MODELS; DYNAMIC OPTIMIZATION; PARAMETERS; FORCE; GAIT; LIMB; ARCHITECTURE; PROGRESSION; MECHANICS;
D O I
10.1016/j.jbiomech.2012.02.023
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Hill-type muscle models are commonly used in musculoskeletal models to estimate muscle forces during human movement. However, the sensitivity of model predictions of muscle function to changes in muscle moment arms and muscle tendon properties is not well understood. In the present study, a three-dimensional muscle-actuated model of the body was used to evaluate the sensitivity of the function of the major lower limb muscles in accelerating the whole-body center of mass during gait. Monte-Carlo analyses were used to quantify the effects of entire distributions of perturbations in the moment arms and architectural properties of muscles. In most cases, varying the moment arm and architectural properties of a muscle affected the torque generated by that muscle about the joint(s) it spanned as well as the torques generated by adjacent muscles. Muscle function was most sensitive to changes in tendon slack length and least sensitive to changes in muscle moment arm. However, the sensitivity of muscle function to changes in moment arms and architectural properties was highly muscle-specific; muscle function was most sensitive in the cases of gastrocnemius and rectus femoris and insensitive in the cases of hamstrings and the medial sub-region of gluteus maximus. The sensitivity of a muscle's function was influenced by the magnitude of the muscle's force as well as the operating region of the muscle on its force-length curve. These findings have implications for the development of subject-specific models of the human musculoskeletal system. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1463 / 1471
页数:9
相关论文
共 35 条
[1]   Moment Arms of the Shoulder Musculature After Reverse Total Shoulder Arthroplasty [J].
Ackland, David C. ;
Roshan-Zamir, Sasha ;
Richardson, Martin ;
Pandy, Marcus G. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (05) :1221-1230
[2]   Dynamic optimization of human walking [J].
Anderson, FC ;
Pandy, MG .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (05) :381-390
[3]   Static and dynamic optimization solutions for gait are practically equivalent [J].
Anderson, FC ;
Pandy, MG .
JOURNAL OF BIOMECHANICS, 2001, 34 (02) :153-161
[4]  
Anderson FRANK C., 1999, Comput Methods Biomech Biomed Engin, V2, P201, DOI 10.1080/10255849908907988
[5]   Knee muscle forces during walking and running in patellofemoral pain patients and pain-free controls [J].
Besier, Thor F. ;
Fredericson, Michael ;
Gold, Garry E. ;
Beaupre, Gary S. ;
Delp, Scott L. .
JOURNAL OF BIOMECHANICS, 2009, 42 (07) :898-905
[6]   Accuracy of generic musculoskeletal models in predicting the functional roles of muscles in human gait [J].
Correa, Tomas A. ;
Baker, Richard ;
Graham, H. Kerr ;
Pandy, Marcus G. .
JOURNAL OF BIOMECHANICS, 2011, 44 (11) :2096-2105
[7]   Contributions of individual muscles to hip joint contact force in normal walking [J].
Correa, Tomas A. ;
Crossley, Kay M. ;
Kim, Hyung J. ;
Pandy, Marcus G. .
JOURNAL OF BIOMECHANICS, 2010, 43 (08) :1618-1622
[8]   Sensitivity of dynamic simulations of gait and dynamometer experiments to hill muscle model parameters of knee flexors and extensors [J].
De Groote, F. ;
Van Campen, A. ;
Junkers, I. ;
De Schutter, J. .
JOURNAL OF BIOMECHANICS, 2010, 43 (10) :1876-1883
[9]   Model-based estimation of muscle forces exerted during movements [J].
Erdemir, Ahmet ;
McLean, Scott ;
Herzog, Walter ;
van den Bogert, Antonle J. .
CLINICAL BIOMECHANICS, 2007, 22 (02) :131-154
[10]   MUSCLE-FIBER ARCHITECTURE IN THE HUMAN LOWER-LIMB [J].
FRIEDERICH, JA ;
BRAND, RA .
JOURNAL OF BIOMECHANICS, 1990, 23 (01) :91-95