IFCC reference system for measurement of hemoglobin Alc in human blood and the National Standardization Schemes in the United States, Japan, and Sweden:: A method-comparison study

被引:549
作者
Hoelzel, W
Weykamp, C
Jeppsson, JO
Miedema, K [1 ]
Barr, JR
Goodall, I
Hoshino, T
John, WG
Kobold, U
Little, R
Mosca, A
Mauri, P
Paroni, R
Susanto, F
Takei, I
Thienpont, L
Umemoto, M
Wiedmeyer, HM
机构
[1] Isala Klinieken, Dept Clin Chem, NL-8000 GM Zwolle, Netherlands
[2] Roche Diagnost GmbH, Penzberg, Germany
[3] SKZL Queen Beatrix Hosp, Winterswijk, Netherlands
[4] Lund Univ, Malmo Univ Hosp, Dept Clin Chem, Malmo, Sweden
[5] Ctr Dis Control & Prevent, Atlanta, GA USA
[6] Austin & Repatriat Med Ctr, Dept Lab Med, Melbourne, Vic, Australia
[7] Inst Biopathol Med, Ono, Japan
[8] Norfolk & Norwich Univ Hosp, Dept Clin Biochem, Norwich, Norfolk, England
[9] Univ Missouri, Sch Med, Columbia, MO USA
[10] Univ Milan, Dept Biomed Sci & Technol, I-20122 Milan, Italy
[11] CNR, Inst Biomed Technol, Milan, Italy
[12] Hosp San Raffaele, Ist Ricovero & Cura Carattere Sci, I-20132 Milan, Italy
[13] German Diabet Res Inst, Dusseldorf, Germany
[14] Keio Univ, Sch Med, Dept Lab Med, Tokyo, Japan
[15] State Univ Ghent, Fac Pharmaceut Sci, Analyt Chem Lab, B-9000 Ghent, Belgium
[16] Stand Reference Ctr, Kawasaki, Kanagawa, Japan
关键词
D O I
10.1373/clinchem.2003.024802
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 [基础医学];
摘要
Background: The national programs for the harmonization of hemoglobin (Hb)A(1c) measurements in the US [National Glycohemoglobin Standardization Program (NGSP)], Japan [Japanese Diabetes Society (JDS)/Japanese Society of Clinical Chemistry (JSCC)], and Sweden are based on different designated comparison methods (DCMs). The future basis for international standardization will be the reference system developed by the IFCC Working Group on HbA(1c) Standardization. The aim of the present study was to determine the relationships between the IFCC Reference Method (RM) and the DCMs. Methods: Four method-comparison studies were performed in 2001-2003. In each study five to eight pooled blood samples were measured by 11 reference laboratories of the IFCC Network of Reference Laboratories, 9 Secondary Reference Laboratories of the NGSP, 3 reference laboratories of the JDS/JSCC program, and a Swedish reference laboratory. Regression equations were determined for the relationship between the IFCC RM and each of the DCMs. Results: Significant differences were observed between the HbA(1c) results of the IFCC RM and those of the DCMs. Significant differences were also demonstrated between the three DCMs. However, in all cases the relationship of the DCMs with the RM were linear. There were no statistically significant differences between the regression equations calculated for each of the four studies; therefore, the results could be combined. The relationship is described by the following regression equations: NGSP-HbA(1c) = 0.915(IFCC-HbA(1c)) + 2.15% (r(2) = 0.998); JDS/JSCC-HbA(1c) = 0.927(IFCC-HbA(1c)) + 1.73% (r(2) = 0.997); Swedish-HbA(1c) = 0.989(IFCC-HbA(1c)) + 0.88% (r(2) = 0.996). Conclusion: There is a firm and reproducible link between the IFCC RM and DCM HbA(1c) values. (C) 2004 American Association for Clinical Chemistry
引用
收藏
页码:166 / 174
页数:9
相关论文
共 35 条
[1]
*ADA, 2001, DIABETES CARE S1, V24, pS1
[2]
Arnquist H, 1997, LAKARTIDNINGEN, V50, P4789
[3]
BISSE E, 1995, CLIN CHEM, V41, P658
[4]
PURIFIED HEMOGLOBIN PREPARATIONS IN THE EVALUATION OF HBA1C DETERMINATION BY ION-EXCHANGE CHROMATOGRAPHY [J].
COHEN, MP ;
WITT, J ;
WU, VY .
ANNALS OF CLINICAL BIOCHEMISTRY, 1993, 30 :265-271
[5]
DEZORZI P, 2000, ACCREDIT QUAL ASSUR, V7, P182
[6]
Preparation of a candidate primary reference material for the international standardisation of HbA1c determinations [J].
Finke, A ;
Kobold, U ;
Hoelzel, W ;
Weykamp, C ;
Miedema, K ;
Jeppsson, JO .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 1998, 36 (05) :299-308
[7]
FLUCKIGER R, 1985, CLIN CHEM, V31, P114
[8]
Goldstein DE, 1986, METHODS DIABETES RES, V2, P475
[9]
HOELZEL W, 1996, J INT FED CLIN CHEM, V9, P62
[10]
Survey and assessment of the actual state of routine measurement of glycohaemoglobin/GHb by commercial methods: Warning to the users and the providers [J].
Hoshine, T ;
Okahashi, M ;
Arai, H .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (9-10) :1551-1562