Steady-state sequence synthesis and its application to efficient fat-suppressed imaging

被引:26
作者
Overall, WR [1 ]
Nishimura, DG [1 ]
Hu, BS [1 ]
机构
[1] Stanford Univ, Dept Elect Engn, Magnet Resonance Syst Res Lab, Stanford, CA 94305 USA
关键词
steady-state free precession; fast imaging; fat suppression; spectrally selective imaging; pulse design;
D O I
10.1002/mrm.10542
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new synthesis algorithm, based on the Shinnar-Le Roux (SLR) transform, can be used to generate fully refocused steady-state pulse sequences with arbitrary magnetization profiles as a function of off-resonant precession. This is accomplished by appropriate periodic oscillation of the RF excitation magnitude and phase from echo to echo. The technique is applied to the design of refocused steady-state free precession (SSFP) sequences with flat profiles, providing the opportunity for banding-artifact-free imaging with steady-state contrast. The algorithm is also used to generate refocused-SSFP sequences with an arbitrarily broad region of attenuated signal. These sequences are implemented and applied to the problem of steady-state fat suppression. Preliminary results show signal levels that agree well with theory, and a broad region of suppressed signal at each echo. Total imaging time is kept identical to that of a standard refocused-SSFP experiment through echo equalization and interleaving. 3D images from the leg of a normal volunteer acquired in 44 s demonstrate the applicability of the technique to fat-suppressed imaging. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:550 / 559
页数:10
相关论文
共 28 条
[1]  
BANGERTER NK, 2001, P 9 ANN M ISMRM GLAS, P1780
[2]   DRIVEN EQUILIBRIUM FOURIER TRANSFORM SPECTROSCOPY . A NEW METHOD FOR NUCLEAR MAGNETIC RESONANCE SIGNAL ENHANCEMENT [J].
BECKER, ED ;
FERRETTI, JA ;
FARRAR, TC .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1969, 91 (27) :7784-&
[3]   STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE [J].
CARR, HY .
PHYSICAL REVIEW, 1958, 112 (05) :1693-1701
[4]   Cine MR angiography of the heart with segmented true fast imaging with steady-state precession [J].
Carr, JC ;
Simonetti, O ;
Bundy, J ;
Li, DB ;
Pereles, S ;
Finn, JP .
RADIOLOGY, 2001, 219 (03) :828-834
[5]  
Coxeter H., 1969, INTRO GEOMETRY
[6]  
DEIMLING M, 2000, P 8 ANN M ISMRM DENV, P1500
[7]   3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries [J].
Deshpande, VS ;
Shea, SM ;
Laub, G ;
Simonetti, OP ;
Finn, JP ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :494-502
[8]   Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at .2 T [J].
Duerk, JL ;
Lewin, JS ;
Wendt, M ;
Petersilge, C .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :203-208
[9]   PHASE AND INTENSITY ANOMALIES IN FOURIER TRANSFORM NMR [J].
FREEMAN, R ;
HILL, HDW .
JOURNAL OF MAGNETIC RESONANCE, 1971, 4 (03) :366-&
[10]  
Golub Gene H., 1996, MATRIX COMPULATIONS, V3rd