Deconvolution-based partial volume correction in Raclopride-PET and Monte Carlo comparison to MR-based method

被引:114
作者
Tohka, Jussi [1 ]
Reilhac, Anthonin [2 ]
机构
[1] Tampere Univ Technol, Inst Signal Proc, FIN-33101 Tampere, Finland
[2] CERMEP, Bron, France
关键词
partial volume effect; striatum; positron emission tomography; simulation; Richardson-Lucy; Van Cittert; total variation;
D O I
10.1016/j.neuroimage.2007.10.038
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
In this work, we evaluated three iterative deconvolution algorithms and compared their performance to partial volume (PV) correction based on structural imaging in brain positron emission tomography (PET) using a database of Monte Carlo-simulated images. We limited our interest to quantitative radioligand PET imaging, particularly to C-11-Raclopride and striatal imaging. The studied deconvolution methods included Richardson-Lucy, reblurred Van Cittert, and reblurred Van Cittert with the total variation regularization. We studied the bias and variance of the regional estimates of binding potential (BP) values and the accuracy of regional TACs as a function of the applied image processing. The resolution/noise tradeoff in parametric BP images was addressed as well. The regional BP values and TACs obtained by deconvolution were almost as accurate than those by structural imaging-based PV correction (GTM method) when the ideal volumes of interests (VOIs) were used to extract TACs from the images. For deconvolution methods, the ideal VOIs were slightly eroded from the exact anatomical VOI to limit the bias due to tissue fraction effect which is not corrected for by deconvolution-based methods. For the GTM method, the ideal VOIs were the exact anatomical VOIs. The BP values and TACs by deconvolution were less affected by segmentation and registration errors than those with the GTM-based PV correction. The BP estimates and TACs with deconvolution-based PV correction were more accurate than BPs and TACs derived without PV correction. The parametric images obtained by the deconvolution-based PV correction showed considerably improved resolution with only slightly increased noise level compared to the case with no PV correction. The reblurred Van Cittert method was the best of the studied deconvolution methods. We conclude that the deconvolution is an interesting alternative to structural imaging-based PV correction as it leads to quantification results of similar accuracy, and it is less prone to registration and segmentation errors than structural imaging-based PV correction. Moreover, PV-corrected parametric images can be readily computed based on deconvolved dynamic images. (C) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:1570 / 1584
页数:15
相关论文
共 42 条
[1]   Positron emission tomography partial volume correction: Estimation and algorithms [J].
Aston, JAD ;
Cunningham, VJ ;
Asselin, MC ;
Hammers, A ;
Evans, AC ;
Gunn, RN .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2002, 22 (08) :1019-1034
[2]   Evaluation of anatomy based reconstruction for partial volume correction in brain FDG-PET [J].
Baete, K ;
Nuyts, J ;
Van Laere, K ;
Van Paesschen, W ;
Ceyssens, S ;
De Ceuninck, L ;
Gheysens, O ;
Kelles, A ;
Van den Eynden, J ;
Suetens, P ;
Dupont, P .
NEUROIMAGE, 2004, 23 (01) :305-317
[3]   ITERATIVE METHODS FOR IMAGE DEBLURRING [J].
BIEMOND, J ;
LAGENDIJK, RL ;
MERSEREAU, RM .
PROCEEDINGS OF THE IEEE, 1990, 78 (05) :856-883
[4]  
BOUSSION N, 2007, UNPUB NEUROIMAGE
[5]   Linear and nonlinear image deblurring: A documented study [J].
Carasso, AS .
SIAM JOURNAL ON NUMERICAL ANALYSIS, 1999, 36 (06) :1659-1689
[6]   2 ITERATIVE IMAGE-RESTORATION ALGORITHMS WITH APPLICATIONS TO NUCLEAR-MEDICINE [J].
CHARALAMBOUS, C ;
GHADDAR, FK ;
KOURIS, K .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (01) :2-8
[7]   AUTOMATIC 3D INTERSUBJECT REGISTRATION OF MR VOLUMETRIC DATA IN STANDARDIZED TALAIRACH SPACE [J].
COLLINS, DL ;
NEELIN, P ;
PETERS, TM ;
EVANS, AC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (02) :192-205
[8]  
Collins DL, 1999, LECT NOTES COMPUT SC, V1613, P210
[9]   IMAGE-RECONSTRUCTION AND RESTORATION - OVERVIEW OF COMMON ESTIMATION STRUCTURES AND PROBLEMS [J].
DEMOMENT, G .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1989, 37 (12) :2024-2036
[10]   Convergence of an iterative method for total variation denoising [J].
Dobson, DC ;
Vogel, CR .
SIAM JOURNAL ON NUMERICAL ANALYSIS, 1997, 34 (05) :1779-1791