Potentiometric Cd2+-selective electrode with a detection limit in the low ppt range

被引:100
作者
Ion, AC
Bakker, E
Pretsch, E
机构
[1] Swiss Fed Inst Technol, Dept Organ Chem, CH-8092 Zurich, Switzerland
[2] Univ Polytech Bucharest, Bucharest, Romania
[3] Auburn Univ, Dept Chem, Auburn, AL 36849 USA
基金
美国国家卫生研究院;
关键词
Cd2+-selective electrode; ion-selective electrodes; potentiometry; low detection limits; trace level analysis;
D O I
10.1016/S0003-2670(01)01052-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A recently introduced model describing the response curves of polymer membrane ion-selective electrodes (ISEs) is used here to optimize a Cd2+-ISE with a view to achieve very low detection limits. In a first step, the selectivity behavior is determined for two membranes based on the ionophore, N,N,N',N'-tetradodecyl-3,6-dioxaoctanedithioamide (ETH 5435), but having different concentrations of the ionophore and ion-exchanger. Based on these data, the optimal response curves are calculated with a model that takes into account the ion fluxes induced by interfering ions. The experimental results with different ionic backgrounds correspond very well with the predicted effects. The best lower detection limit of 10(-10) M or 11 ppt Cd2+ is achieved at pH 7 with an ionic background of 10(-4) M NaNO3. (C) 2001 Elsevier Science B.V. All lights reserved.
引用
收藏
页码:71 / 79
页数:9
相关论文
共 30 条
[1]  
[Anonymous], 1964, SPECIAL PUBLICATION
[2]  
[Anonymous], 1976, PURE APPL CHEM, V48, P127, DOI DOI 10.1351/PAC197648010127
[3]   Determination of unbiased selectivity coefficients of neutral carrier-based cation-selective electrodes [J].
Bakker, E .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1061-1069
[4]  
Bakker E, 1999, ELECTROANAL, V11, P915, DOI 10.1002/(SICI)1521-4109(199909)11:13<915::AID-ELAN915>3.0.CO
[5]  
2-J
[6]   Potentiometry at trace levels [J].
Bakker, E ;
Pretsch, E .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (01) :11-19
[7]   Determination of improved selectivity coefficients of polymer membrane ion-selective electrodes by conditioning with a discriminated ion [J].
Bakker, E .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1996, 143 (04) :L83-L85
[8]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[9]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[10]   Potentiometric polymeric membrane electrodes for measurement of environmental samples at trace levels:: New requirements for selectivities and measuring protocols, and comparison with ICPMS [J].
Ceresa, A ;
Bakker, E ;
Hattendorf, B ;
Günther, D ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 2001, 73 (02) :343-351