Evaluation of microbial samplers for bacterial microorganisms

被引:81
作者
Li, CS [1 ]
Hao, ML
Lin, WH
Chang, CW
Wang, CS
机构
[1] Natl Taiwan Univ, Grad Inst Environm Hlth, Coll Publ Hlth, Taipei, Taiwan
[2] Council Labor, Inst Occupat Safety & Hlth, Taipei, Taiwan
关键词
D O I
10.1080/027868299304705
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The influences of physical factors, sampling time, and how rates on total recovery rate of airborne bacteria were evaluated in a chamber by three sampling methods: AGI-30 all-glass impingers, Nuclepore filtration and elution method, and gelatin filters. The influence of the biological factor, microorganism hardiness, was assessed by using sensitive Escherichia coli (E. coli) and hardy Bacillus subtilis (B. subtilis) spores. It was found that colony or relative survival of sensitive E, coli was much lower than those of hardy B, subtilis spores by the evaluated three sampling methods. Sampling flow rate did not have a significant influence on the bacterial recovery by the three sampling methods, However, the relative survival of sensitive E, coli collected on Nuclepore and gelatin filters became lower as the sampling time increased because of dehydration effects. For hardy B, subtilis spores, it was demonstrated that recovery by gelatin filter was comparable to that by impinger. In conclusion, it was found that impingers could perform much better than filtration methods for sampling airborne bacterial bioaerosols.
引用
收藏
页码:100 / 108
页数:9
相关论文
共 19 条
[1]  
BRACHMAN PS, 1964, SCIENCE, V144, P1295
[2]  
Crook B., 1995, P269
[3]   THE ASSESSMENT OF BIOAEROSOLS - A CRITICAL-REVIEW [J].
GRIFFITHS, WD ;
DECOSEMO, GAL .
JOURNAL OF AEROSOL SCIENCE, 1994, 25 (08) :1425-1458
[4]   Effect of impaction, bounce and reaerosolization on the collection efficiency of impingers [J].
Grinshpun, SA ;
Willeke, K ;
Ulevicius, V ;
Juozaitis, A ;
Terzieva, S ;
Donnelly, J ;
Stelma, GN ;
Brenner, KP .
AEROSOL SCIENCE AND TECHNOLOGY, 1997, 26 (04) :326-342
[5]   EVALUATION OF MICROBIOLOGICAL AEROSOL SAMPLERS - A REVIEW [J].
HENNINGSON, EW ;
AHLBERG, MS .
JOURNAL OF AEROSOL SCIENCE, 1994, 25 (08) :1459-1492
[6]  
JENSEN PA, 1992, AM IND HYG ASSOC J, V53, P660, DOI 10.1202/0002-8894(1992)053<0660:EOEBSC>2.0.CO
[7]  
2
[8]   PRECISION OF THE ALL-GLASS IMPINGER AND THE ANDERSEN MICROBIAL IMPACTOR FOR AIR SAMPLING IN SOLID-WASTE HANDLING FACILITIES [J].
LEMBKE, LL ;
KNISELEY, RN ;
VANNOSTRAND, RC ;
HALE, MD .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1981, 42 (02) :222-225
[9]   Effect of sampling time on the collection efficiency of all-glass impingers [J].
Lin, XJ ;
Willeke, K ;
Ulevicius, V ;
Grinshpun, SA .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1997, 58 (07) :480-488
[10]  
MACHER JM, 1984, AM IND HYG ASSOC J, V45, P76, DOI 10.1202/0002-8894(1984)045<0076:PASFMO>2.3.CO