Disposable amperometric glucose sensor electrode with enzyme-immobilized nitrocellulose strip

被引:50
作者
Cui, G [1 ]
Yoo, JH [1 ]
Woo, BW [1 ]
Kim, SS [1 ]
Cha, GS [1 ]
Nam, H [1 ]
机构
[1] Kwangwoon Univ, Dept Chem, Chem Sensor Res Grp, Nowon Ku, Seoul 139701, South Korea
关键词
amperometric glucose sensor; hexamineruthenium (III) chloride mediator; nitrocellulose strip; carbon paste electrode;
D O I
10.1016/S0039-9140(01)00377-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemical properties of screen-printed carbon paste electrodes (CPEs) with a glucose oxidase-immobilized and hexamineruthenium (III) chloride ([Ru(NH3)(6)](3+)) containing nitrocellulose (NC) strip were examined. The NC strip (2 x 8 mm) placed on the CPEs printed on polyester (PE) film is tightly sealed using another PE film on the top with open edges on both sides. Samples containing macromolecules and particles (e.g. proteins and blood cells) are applied at one edge of the NC strip and reach the detection area, chromatographically separating small molecules (e.g. glucose, ascorbate, acetaminophen, and uric acid) of analytical interests. Since sample volumes and the amount of catalytic reagents (mediator and glucose oxidase) are precisely predefined by the dimension and pore size (8 mum) of the NC strip, the sensor-to-sensor reproducibility and accuracy of analysis are greatly improved. The use of [Ru(NH3)(6)](3+) mediator, which exhibits characteristic substantially lowers the applied potential (0.0 V vs Ag/AgCl) for glucose determination and eliminates the interference from other oxidizable species, providing improved analytical results. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1105 / 1111
页数:7
相关论文
共 28 条
[1]  
AMINE A, 1989, ANAL LETT, V22, P2403
[2]  
ATRASH SSE, 1995, ELECTROCHIM ACTA, V40, P2791
[3]   RAPID-DETERMINATION OF THE GLUCOSE CONTENT OF MOLASSES USING A BIOSENSOR [J].
BRADLEY, J ;
KIDD, AJ ;
ANDERSON, PA ;
DEAR, AM ;
ASHBY, RE ;
TURNER, APF .
ANALYST, 1989, 114 (03) :375-379
[4]   SCREEN PRINTED GLUCOSE ELECTRODES BASED ON PLATINIZED CARBON PARTICLES AND GLUCOSE-OXIDASE [J].
CARDOSI, MF ;
BIRCH, SW .
ANALYTICA CHIMICA ACTA, 1993, 276 (01) :69-74
[5]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[6]   ELECTRON EXCHANGE BETWEEN FLAVIN-CONTAINING AND HEME-CONTAINING ENZYMES AND ELECTRODES MODIFIED BY REDOX POLYMERS [J].
CENAS, NK ;
POCIUS, AK ;
KULYS, JJ .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1983, 11 (01) :61-73
[7]   ARE BLOOD-GLUCOSE REAGENT STRIPS RELIABLE IN RENAL-FAILURE [J].
CLARK, JDA ;
GOLDBERG, L ;
JONES, K ;
HARTOG, M .
DIABETIC MEDICINE, 1991, 8 (02) :168-171
[8]   MEDIATED, ANAEROBIC VOLTAMMETRY OF SULFITE OXIDASE [J].
COURY, LA ;
OLIVER, BN ;
EGEKEZE, JO ;
SOSNOFF, CS ;
BRUMFIELD, JC ;
BUCK, RP ;
MURRAY, RW .
ANALYTICAL CHEMISTRY, 1990, 62 (05) :452-458
[9]   THE ELECTROCHEMISTRY OF HEXACYANORUTHENATE AT CARBON ELECTRODES AND THE USE OF RUTHENIUM COMPOUNDS AS MEDIATORS IN THE GLUCOSE GLUCOSE-OXIDASE SYSTEM [J].
CRUMBLISS, AL ;
HILL, HAO ;
PAGE, DJ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1986, 206 (1-2) :327-331
[10]  
CSOREGI E, 1994, ANAL CHEM, V66, P3131