Heparinization of gas plasma-modified polystyrene surfaces and the interactions of these surfaces with proteins studied with surface plasmon resonance

被引:20
作者
vanDelden, CJ
Lens, JP
Kooyman, RPH
Engbers, GHM
Feijen, J
机构
[1] UNIV TWENTE,DEPT CHEM ENGN,BIOMAT SECT,NL-7500 AE ENSCHEDE,NETHERLANDS
[2] INST BIOMED TECHNOL,ENSCHEDE,NETHERLANDS
[3] UNIV TWENTE,DEPT APPL PHYS,APPL OPT GRP,NL-7500 AE ENSCHEDE,NETHERLANDS
关键词
surface plasmon resonance; heparinization; protein-surface interactions;
D O I
10.1016/S0142-9612(96)00209-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polystyrene surfaces obtained by spin-coating a solution of polystyrene in toluene on a gold layer were functionalized with carboxylic acid groups by preadsorption of the sodium salt of undecylenic acid, followed by an argon plasma treatment. A conjugate of albumin and heparin (alb-hep) was covalently immobilized onto the functionalized surface via preactivation of carboxylic acid groups with a water-soluble carbodiimide. The immobilization of alb-hep conjugate and the subsequent interactions of the heparinized surface with antithrombin III (ATIII, a heparin cofactor) and thrombin were monitored with surface plasmon resonance (SPR). The surface concentration of conjugate as determined with SPR deviated quantitatively from the results obtained with radiolabelled conjugate. The difference in surface concentrations of conjugate obtained with the two methods probably originates from the uncertainty of the refractive index of the alb-hep conjugate in the SPR technique. ATIII could be bound to the surface modified with alb-hep conjugate but not to a polystyrene surface modified with albumin. Rabbit anti-human ATIII did bind to the alb-hep surface previously exposed to ATIII, confirming the presence of surface bound ATIII. The alb-hep immobilized surface was able to bind much more thrombin than ATIII, which is probably due to the less specific heparin-thrombin interaction as compared to the heparin-ATIII interaction. This study shows that SPR is a technique that can be used to study, in real time, both the modification of polymer surfaces and the subsequent interactions of the modified surfaces with proteins. (C) 1997 Elsevier Science Limited.
引用
收藏
页码:845 / 852
页数:8
相关论文
共 18 条
[1]  
BRANDRUP J, 1989, POLYM HDB
[2]   PLASMA-DEPOSITED POLYMERIC FILMS PREPARED FROM CARBONYL-CONTAINING VOLATILE PRECURSORS - XPS CHEMICAL DERIVATIZATION AND STATIC SIMS SURFACE CHARACTERIZATION [J].
CHILKOTI, A ;
RATNER, BD ;
BRIGGS, D .
CHEMISTRY OF MATERIALS, 1991, 3 (01) :51-61
[3]  
CREIGHTON TE, 1983, PROTEINS
[4]  
ENGBERS GHM, 1990, THESIS U TWENTE
[5]  
Jonsson U., 1992, ADV BIOSENSORS, V2, P291, DOI DOI 10.1016/B978-1-85617-161-8.50079-3
[6]   SURFACE-PLASMON RESONANCE IMMUNOSENSORS - SENSITIVITY CONSIDERATIONS [J].
KOOYMAN, RPH ;
KOLKMAN, H ;
VANGENT, J ;
GREVE, J .
ANALYTICA CHIMICA ACTA, 1988, 213 (1-2) :35-45
[7]   VIBRATING MIRROR SURFACE-PLASMON RESONANCE IMMUNOSENSOR [J].
KOOYMAN, RPH ;
LENFERINK, ATM ;
EENINK, RG ;
GREVE, J .
ANALYTICAL CHEMISTRY, 1991, 63 (01) :83-85
[8]   AN IMPROVED OPTICAL METHOD FOR SURFACE-PLASMON RESONANCE EXPERIMENTS [J].
LENFERINK, ATM ;
KOOYMAN, RPH ;
GREVE, J .
SENSORS AND ACTUATORS B-CHEMICAL, 1991, 3 (04) :261-265
[9]   SURFACE-PLASMON RESONANCE FOR GAS-DETECTION AND BIOSENSING [J].
LIEDBERG, B ;
NYLANDER, C ;
LUNDSTROM, I .
SENSORS AND ACTUATORS, 1983, 4 (02) :299-304
[10]   IMMUNOASSAY BASED ON SURFACE-PLASMON OSCILLATIONS [J].
MAYO, CS ;
HALLOCK, RB .
JOURNAL OF IMMUNOLOGICAL METHODS, 1989, 120 (01) :105-114