Purpose. Failure mode and effects analysis (FMEA) was used to identify dosing and administration errors associated with i.v. medications and evaluate the effectiveness of subsequent system improvements. Summary. A multidisciplinary medication safety team conducted an FMEA to identify and reduce common medication errors and selected wrong-dose errors for process improvement. In 2002, wrong-dose errors comprised 17% of all medication errors at the hospital (59 of 347 errors). The most common reason for administering the wrong dose was error in programming the i.v. infusion pump (41%). Potential errors (i.e., failures) identified were misinterpretation of the order, removing the wrong medication or wrong concentration of the correct medication, using the wrong diluent or drug to prepare the drip, and entering the wrong concentration or infusion rate on the pump. Errors in programming the i.v. infusion pump was the step in the medication-use process associated with the highest criticality index. Based on the results of the FMEA, two main interventions were performed. First, standard order sets were revised after streamlining the formulary and eliminating the use of unapproved abbreviations. Second, an i.v. pump with enhanced safety features was implemented. One-year follow-up data revealed that the number of medication errors related to dosing (wrong dose or incorrect infusion rate) had decreased slightly (from 59 in 2002 to 46 in 2003); however, a dramatic reduction was noted in the percentage of pump-related errors. In 2003, pump-related errors accounted for 22% of dosing errors, compared with 41% in 2002. Conclusion. Medication errors related to i.v. infusion pumps were reduced by conducting an FMEA and implementing the process changes needed.
引用
收藏
页码:917 / 920
页数:4
相关论文
共 10 条
[1]  
[Anonymous], 1999, ERR HUMAN BUILDING S
[2]  
Cohen M R, 1994, Hosp Pharm, V29, P319
[3]  
COHEN MR, 1994, HOSP PHARM, V29, P330
[4]  
COHEN MR, 1994, HOSP PHARM, V29, P326
[5]  
Cohen RD, 1999, INFLAMM BOWEL DIS, V5, P1
[6]  
Grissinger M., 2003, PHARMACOL THERAPEUT, V28, P8
[7]  
*I SAF MED PRACT, ISMP MED SAF ALERT F
[8]  
*JOINT COMM ACC HL, FMECA WORKSH
[9]  
*JOINT COMM ACCR H, ORG 2005 HOSP NAT PA
[10]  
Spath P., 2003, Association of periOperative Registered Nurses (AORN) Journal, V78, P15, DOI DOI 10.1016/S0001-2092(06)61343-4