Hydride generation atomic absorption spectrometry with different flow systems and in-atomizer trapping for determination of cadmium in water and urine - Overview of existing data on cadmium vapour generation and evaluation of critical parameters

被引:51
作者
Lampugnani, L
Salvetti, C
Tsalev, DL
机构
[1] CNR, Ist Proc Chimicofis, Area Ric Pisa, I-56124 Pisa, Italy
[2] Univ Sofia, Fac Chem, Sofia 1164, Bulgaria
关键词
cadmium determination; hydride generation-electrothermal atomic absorption spectrometry; graphite atomizer; gas-liquid separators;
D O I
10.1016/S0039-9140(03)00324-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An overview of literature data on vapour generation techniques for cadmium and comparison with own experiments by means of several different types of hydride generation-electrothermal atomic absorption spectrometric systems (HG-ETAAS) (batch, semi-batch (SB), continuous-flow (CF) and flow-injection (FI) as well as different gas-liquid separators (GLS) exhibits apparent variations and inconsistency. However, if data for optimal chemical conditions are re-plotted in another coordinates: C-HCl (mol 1(-1)) vs. the ratio of reductant-to-acid molar input rates (i.e. millimoles per minute), [BH4-]:[H+], much better consistency of data is revealed: more than half of data are clustered around 0.2-0.3 mol 1(-1) HCl which appears an optimal acidity at moderate BH4- concentrations; the tetrahydroborate molar input rates should always be in excess versus the H+ molar input rates (1.1 to tenfold); relatively high flow rates of argon purge gas are required (greater than or equal to 120 ml min(-1)); special attention to the blank control at ng 1(-1) levels as well as to the construction of gas-liquid separator and vapour transfer lines should be paid. 'Milder' conditions for HG could be provided with some of the examined systems and GLSs, thus minimizing reagent consumption, blanks, vigorous reactions, foaming, aerosol production and drift in measurements: e.g. 0.4 mol 1(-1) HCl-3% m/v NaBH4 with the semi-batch system and 0.25 mol 1(-1) HCl-2% m/v NaBH4 in continuous flow mode. Experimental system is based on the Transversely Heated Graphite Atomizer coupled with flow injection system FIAS 400. Integrated platforms are treated for permanent modification with Zr (110 mug) or W (240 mug) and then with Ir (8 mug). Temperatures of trapping, pyrolysis and atomization are 350, 500 and 1300 degreesC, respectively. The best overall efficiency of HG, transportation and trapping is 41%. The characteristic mass for peak area measurements is m(o) = 2.8 pg and the limit of detection is 0.002 mug 1(-1). The long-term stability of characteristic mass (within-day, 8 h) is m(o) = 2.8+/-0.1 pg (R.S.D. 4.0%, n = 8), whereas the corresponding between-day figures (1 mo) are m(o) = 2.8+/-0.2 pg (R.S.D. 6.6%, n = 6). The linear range is 0.002-0.12 mug 1(-1) with a sample loop of 1.8 ml, being strongly impaired with smaller sample volumes in FI mode. The sample throughput rate is 10 h(-1) with the semi-batch system. Applications to real human and bovine urine samples and CRMs of sea water (CASS-3), river water (SLRS-1 and SLRS-3) and urine (SRM 2670) are presented. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:683 / 698
页数:16
相关论文
共 45 条
[1]   THE PREPARATION OF THE HYDRIDES OF ZINC, CADMIUM, BERYLLIUM, MAGNESIUM AND LITHIUM BY THE USE OF LITHIUM ALUMINUM HYDRIDE [J].
BARBARAS, GD ;
DILLARD, C ;
FINHOLT, AE ;
WARTIK, T ;
WILZBACH, KE ;
SCHLESINGER, HI .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1951, 73 (10) :4585-4590
[2]  
Bermejo-Barrera P, 1998, ATOM SPECTROSC, V19, P100
[3]   Use of flow injection cold vapour generation and preconcentration on coated graphite tubes for the determination of cadmium in sea-water by electrothermal atomic absorption spectrometry [J].
BermejoBarrera, P ;
MoredaPineiro, J ;
MoredaPineiro, A ;
BermejoBarrera, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (11) :1081-1086
[4]   On the behaviour of cysteine as ligand of cadmium(II) [J].
Bottari, E ;
Festa, MR .
TALANTA, 1997, 44 (10) :1705-1718
[5]   GENERATION OF A VOLATILE CADMIUM SPECIES IN AN ORGANIC MEDIUM [J].
CACHO, J ;
BELTRAN, I ;
NERIN, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (07) :661-663
[6]  
Cotton F.A, 1972, ADV INORG CHEM, P115
[7]  
De Giglio E, 2000, SURF INTERFACE ANAL, V29, P747, DOI 10.1002/1096-9918(200011)29:11<747::AID-SIA922>3.3.CO
[8]  
2-2
[9]  
DEDINA J, 1995, HYDRIDE GENERATION A
[10]  
DELACAMPA MRF, 1995, SPECTROCHIM ACTA B, V50, P377