Several image reconstruction algorithms based on rebinning have been proposed recently for helical cone-beam CT. These algorithms separate the 3D reconstruction into a set of independent 2D reconstructions for a set of surfaces: planar or non-planar surfaces are defined and then reconstructed using 2D filtered backprojection from a 2D fan-beam or parallel-beam set of data estimated from the cone-beam (CB) measurements. The first part of this paper presents a unified derivation of rebinning algorithms for planar and nonplanar surfaces. An integral equation is derived for the surface allowing the best rebinning and an iterative algorithm converging to the solution of that equation is given. The second part presents an efficient method to correct the residual reconstruction artefacts observed with rebinning algorithms when the cone-anale is too large for the required accuracy. This correction algorithm involves a CB backprojection and the reconstruction time is slightly longer than for the zero-boundary (ZB) method.
引用
收藏
页码:2911 / 2937
页数:27
相关论文
共 33 条
[1]  
Bruder H, 2000, IEEE T MED IMAGING, V19, P873, DOI 10.1109/42.887836
[2]  
DANIELSSON PE, 1997, P 1997 INT M FULL 3, P141
[3]   A solution to the long-object problem in helical cone-beam tomography [J].
Defrise, M ;
Noo, F ;
Kudo, H .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (03) :623-643
[4]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[5]  
GRANGEAT P, 1991, LECT NOTES MATH, V1497, P66
[6]  
HEUSCHER D, 1999, INT M FULL 3 DIM IM, P204
[7]   Advanced single-slice rebinning in cone-beam spiral CT [J].
Kachelriess, M ;
Schaller, S ;
Kalender, WA .
MEDICAL PHYSICS, 2000, 27 (04) :754-772
[8]  
Kak AC, 1987, PRINCIPLES COMPUTERI
[9]   Quasi-exact filtered backprojection algorithm for long-object problem in helical cone-beam tomography [J].
Kudo, H ;
Noo, F ;
Defrise, M .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (09) :902-921
[10]   Performance of quasi-exact cone-beam filtered backprojection algorithm for axially truncated helical data [J].
Kudo, H ;
Park, S ;
Noo, F ;
Defrise, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :608-617