Monitoring for compartmental syndrome using near-infrared spectroscopy: A noninvasive, continuous, transcutaneous monitoring technique

被引:77
作者
Garr, JL
Gentilello, LM
Cole, PA
Mock, CN
Matsen, FA
机构
[1] Univ Washington, Harborview Med Ctr, Sch Med, Dept Surg, Seattle, WA 98104 USA
[2] Univ Washington, Harborview Med Ctr, Sch Med, Dept Orthoped, Seattle, WA 98104 USA
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 1999年 / 46卷 / 04期
关键词
near-infrared spectroscopy; compartmental syndromes; oximetry; orthopedics; fractures; traumatology;
D O I
10.1097/00005373-199904000-00009
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The diagnosis of compartmental syndrome (CS) may be delayed because current monitoring techniques are invasive and intermittent and the compartment pressure (CP) that predicts ischemia is variable. Fiber-optic devices using near-infrared (NIR) wavelength reflection can determine the redox state of light-absorbing molecules and have been used to monitor venous hemoglobin saturation to detect ischemia during low-flow states. The purpose of this study was to determine if NIR spectroscopy can provide continuous, transcutaneous, noninvasive monitoring for muscle ischemia in an animal model of CS. Methods: Nine swine were anesthetized and a 20-mm NTR probe was placed over the anterolateral compartment of the hind leg to provide continuous determination of muscle oxyhemoglobin level. Needles were inserted into the compartment to measure CP, A nerve stimulator was placed over the peroneal nerve to induce dorsiflexion twitch, Albumin was infused into the muscle to incrementally increase CP until there was complete loss of dorsiflexion, then after 20 minutes fasciotomy was performed. Results: All animals lost dorsiflexion at CP of 43 +/- 14 mm Hg. There was a significant inverse correlation between CP and oxyhemoglobin level (r = -0.78; p < 0.001) and a correlation between oxyhemoglobin and perfusion pressure (mean arterial pressure minus CP) (r = 0.66; p < 0.001). Redox state was a more consistent predictor of twitch loss than perfusion pressure. Conclusion: Muscle oxyhemoglobin level measured by NIR spectroscopy strongly reflected CP, perfusion pressure, and loss of dorsiflexion twitch, Currently available portable NIR devices may provide the benefit of continuous, noninvasive monitoring for CS, Further studies to determine the role of this technology in the detection of compartmental syndrome are warranted.
引用
收藏
页码:613 / 616
页数:4
相关论文
共 19 条
[1]  
Altman DG, 1990, PRACTICAL STAT MED R
[2]   The future - Monitoring cellular energetics [J].
Beilman, GJ ;
Cerra, FB .
CRITICAL CARE CLINICS, 1996, 12 (04) :1031-&
[3]  
BERMUDEZ D, 1997, J TRAUMA, V42, P162
[4]   Lower limb compartment syndrome: Course after delayed fasciotomy [J].
Finkelstein, JA ;
Hunter, GA ;
Hu, RW .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1996, 40 (03) :342-344
[5]   A COMPARATIVE-STUDY OF THE TOLERANCE OF SKELETAL-MUSCLE TO ISCHEMIA - TOURNIQUET APPLICATION COMPARED WITH ACUTE COMPARTMENT SYNDROME [J].
HEPPENSTALL, RB ;
SCOTT, R ;
SAPEGA, A ;
PARK, YS ;
CHANCE, B .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (06) :820-828
[6]   VALIDATION OF NEAR-INFRARED SPECTROSCOPY IN HUMANS [J].
MANCINI, DM ;
BOLINGER, L ;
LI, H ;
KENDRICK, K ;
CHANCE, B ;
WILSON, JR .
JOURNAL OF APPLIED PHYSIOLOGY, 1994, 77 (06) :2740-2747
[7]  
MARS M, 1994, S AFR J SURG, V32, P48
[8]  
Mars M., 1994, Injury, V25, P379, DOI 10.1016/0020-1383(94)90130-9
[9]   MODEL COMPARTMENTAL SYNDROME IN MAN WITH PARTICULAR REFERENCE TO QUANTIFICATION OF NERVE FUNCTION [J].
MATSEN, FA ;
MAYO, KA ;
KRUGMIRE, RB ;
SHERIDAN, GW ;
KRAFT, GH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (05) :648-653
[10]   DEEP POSTERIOR COMPARTMENTAL SYNDROME OF LEG [J].
MATSEN, FA ;
CLAWSON, DK .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1975, A 57 (01) :34-39