Characterization and corrosion studies of fluoride conversion coating on degradable Mg implants

被引:361
作者
Chiu, K. Y.
Wong, M. H.
Cheng, F. T. [1 ]
Man, H. C.
机构
[1] Hong Kong Polytech Univ, Dept Appl Phys, Kowloon, Hong Kong, Peoples R China
[2] Hong Kong Polytech Univ, Dept Ind & Syst Engn, Kowloon, Hong Kong, Peoples R China
关键词
magnesium; degradable implant material; conversion coating; magnesium fluoride; corrosion resistance;
D O I
10.1016/j.surfcoat.2007.06.035
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Fluoride conversion coating was synthesized on magnesium (Mg) by immersion treatment in hydrofluoric acid (HF) at room temperature, with the aim of improving the corrosion resistance of Mg in applications as degradable implant material. After an immersion period of 24 h in 48% HE, the samples carried a bronze color, and the conversion coating was dense and free of cracks. Field-emission scanning-electron microscopy (FE-SEM) of the cross-section revealed a coating thickness of about 1.5 mu m. Atomic-force microscopy (AFM) recorded an average surface roughness of similar to 21 mn for the coated sample, similar to that of the untreated one (similar to 17 nm). The coating was mainly composed of magnesium fluoride (MgF2) as identified by thin-film X-ray diffractometry (TF-XRD), consistent with compositional analysis using X-ray photoclectron spectroscopy (XPS). The MgF2 was in the form of crystallites of a few nm. A small amount of oxygen was present inside the coating, suggesting that some F- ions are replaced by hydroxyl (OH-) ions in the MgF2, structure, or that a small amount of Mg(OH)2 was present. The corrosion resistance of untreated and conversion coated Mg in Hanks' solution was studied using electrochemical impedance spectroscopy (EIS), potentiodynamic polarization tests, and immersion tests. EIS results showed a polarization resistance of 0.18 k Omega cm(2) for the untreated Mg and 5.2 k Omega cm(2) for the coated sample, giving an improvement of about 3 0 times. Polarization tests also recorded a reduction in corrosion current density from 400 mu A/cm(2) to 10 mu A/cm(2), showing an improvement of about 40 times. The galvanic effect between untreated and fluoride-coated Mg samples was small. himiersion tests in Hanks' solution also resulted in a much milder and more uniform corrosion damage on the fluoride-coated samples. The results of the present study showed that fluoride coating by conversion treatment is a simple and promising way of enhancing the corrosion resistance of Mg in Hanks' solution, or that it may be employed as a pretreatment step for subsequent coating. (c) 2007 Elsevier B.V All rights reserved.
引用
收藏
页码:590 / 598
页数:9
相关论文
共 38 条
[1]   Surface modification of magnesium by NaHCO3 and corrosion behavior in Hank's solution for new biomaterial applications [J].
Al-Abdullat, Y ;
Tsutsumi, S ;
Nakajima, N ;
Ohta, M ;
Kuwahara, H ;
Ikeuchi, K .
MATERIALS TRANSACTIONS, 2001, 42 (08) :1777-1780
[2]  
[Anonymous], ELECTROCHIM ACTA
[3]  
*ASTM, 1990, G190 ASTM
[4]  
ASTM, 1994, G594 ASTM
[5]  
*ASTM, 1990, G3190 ASTM
[6]  
*ASTM, 1994, G7181 ASTM
[7]  
*ASTM, 2004, G10589 ASTM
[8]   ALLOY SPUTTERING [J].
BETZ, G .
SURFACE SCIENCE, 1980, 92 (01) :283-309
[9]  
EPELBOIN I, 1981, ASTM STP, V727, P150
[10]   Protective coatings on magnesium and its alloys - a critical review [J].
Gray, JE ;
Luan, B .