Robotically assisted microsurgery for endoscopic coronary artery bypass grafting

被引:71
作者
Stephenson, ER [1 ]
Sankholkar, S [1 ]
Ducko, CT [1 ]
Damiano, RJ [1 ]
机构
[1] Penn State Univ, Milton S Hershey Med Ctr, Penn State Geisinger Hlth Syst, Dept Surg,Div Cardiothorac & Vasc Surg, Hershey, PA 17033 USA
关键词
D O I
10.1016/S0003-4975(98)00656-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. As minimally invasive approaches to cardiac surgery have expanded, a significant number of limitations have become apparent, particularly the lack of adequate precision with standard endoscopic instruments. We hypothesized that the use of robotics would eliminate some of these limitations. Methods. Twenty-five coronary anastomoses on an isolated porcine heart, using an arterial conduit to the left anterior descending artery, were performed endoscopically with a microsurgical robotic system. Sophisticated robotic engineering was used to control modified endoscopic instruments under direct surgeon control. Computer tremor elimination and motion scaling allowed for precise maneuvering. An arteriotomy was placed in the left anterior descending artery, and an arterial conduit was positioned for anastomosis. The camera and port sites were placed 90 degrees from the long axis of the arteriotomy. A 7-0 Prolene (Ethicon, Somerville, NJ) suture was used to perform the anastomosis in a continuous fashion, begun at the 12 o'clock position and continued counterclockwise. After completion of half of the anastomosis, the conduits were pulled down and the final sutures were placed. The sutures were tied intracorporeally and the procedure was completed. Results. The 25 conduits were successfully completed and showed good probe patency. Average time for completion of the anastomosis was 31.7 +/- 2.0 minutes. Appropriate port placement and orientation, and stabilization of the conduits were critical. The lack of tremor and motion scaling allowed for the precise movements needed to complete an endoscopic microvascular anastomosis. Conclusions. Coronary artery anastomoses are technically feasible with use Of robotic instrumentation. This technology may enable the development of a truly endoscopic approach to bypass surgery.
引用
收藏
页码:1064 / 1067
页数:4
相关论文
共 18 条
  • [1] DIRECT MYOCARDIAL REVASCULARIZATION WITHOUT EXTRACORPOREAL-CIRCULATION - EXPERIENCE IN 700 PATIENTS
    BENETTI, FJ
    NASELLI, G
    WOOD, M
    GEFFNER, L
    [J]. CHEST, 1991, 100 (02) : 312 - 316
  • [2] Minimally invasive coronary artery bypass grafting: On the beating heart and via limited access
    Borst, C
    Santamore, WP
    Smedira, NG
    Bredee, JJ
    [J]. ANNALS OF THORACIC SURGERY, 1997, 63 (06) : S1 - S5
  • [3] Coronary artery bypass grafting without cardiopulmonary bypass
    Buffolo, E
    deAndrade, JCS
    Branco, JNR
    Teles, CA
    Aguiar, LF
    Gomes, WJ
    [J]. ANNALS OF THORACIC SURGERY, 1996, 61 (01) : 63 - 66
  • [4] Left anterior descending coronary artery grafting via left anterior small thoracotomy without cardiopulmonary bypass
    Calafiore, AM
    DiGiammarco, G
    Teodori, G
    Bosco, G
    DAnnunzio, E
    Barsotti, A
    Maddestra, N
    Paloscia, L
    Vitolla, G
    Sciarra, A
    Fino, C
    Contini, M
    [J]. ANNALS OF THORACIC SURGERY, 1996, 61 (06) : 1658 - 1663
  • [5] Port-access cardiac operations with cardioplegic arrest
    Fann, JI
    Pompili, MF
    Stevens, JH
    Siegel, LC
    Goar, FGS
    Burdon, TA
    Reitz, BA
    [J]. ANNALS OF THORACIC SURGERY, 1997, 63 (06) : S35 - S39
  • [6] FANN JI, 1997, J AM COLL CARDIOL S, V29, pA466
  • [7] FONGER JD, 1996, CIRCULATION S, V94, P51
  • [8] ROBOTIC INTERACTIVE LAPAROSCOPIC CHOLECYSTECTOMY
    GAGNER, M
    BEGIN, E
    HURTEAU, R
    POMP, A
    [J]. LANCET, 1994, 343 (8897) : 596 - 597
  • [9] GUNDRY SR, 1996, CIRCULATION S1, V94, P52
  • [10] COMPARISON OF ROBOTIC VERSUS HUMAN LAPAROSCOPIC CAMERA CONTROL
    KAVOUSSI, LR
    MOORE, RG
    ADAMS, JB
    PARTIN, AW
    [J]. JOURNAL OF UROLOGY, 1995, 154 (06) : 2134 - 2136