Registration using tomographic projection files

被引:19
作者
Fitchard, EE [1 ]
Aldridge, JS [1 ]
Ruchala, K [1 ]
Fang, G [1 ]
Balog, J [1 ]
Pearson, DW [1 ]
Olivera, GH [1 ]
Schloesser, EA [1 ]
Wenman, D [1 ]
Reckwerdt, PJ [1 ]
Mackie, TR [1 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
关键词
D O I
10.1088/0031-9155/44/2/015
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An algorithm has been developed and experimentally verified for tomographic registration-a patient positioning method using internal anatomy and standard external fiducial marks. This algorithm improves patient set-up and verification to an accuracy sufficient for tomotherapy. By implementation of this technique, the time-consuming reconstruction process is avoided. Instead, offsets in the x, y and z directions are determined directly from sinogram data by an algorithm that utilizes cross-correlations and Fourier transforms. To verify the efficiency and stability of the algorithm, data were collected on the University of Wisconsin's dedicated tomotherapy research workbench. The experiment indicates offset statistical errors of less than +/-0.8 mm for offsets up to 30 mm. With standard clinical techniques, initial patient offsets are expected to be less than 5 mm, so the 30 mm limitation is of no consequence. The angular resolution for the direction of patient translation is within the +/-2 degrees needed for tomotherapy.
引用
收藏
页码:495 / 507
页数:13
相关论文
共 17 条
  • [1] AAPM, 1984, 13 AAPM AM I PHYS
  • [2] IMAGE ALIGNMENT BY INTEGRATED ROTATIONAL AND TRANSLATIONAL TRANSFORMATION MATRIX
    BANERJEE, PK
    TOGA, AW
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (11) : 1969 - 1988
  • [3] CHEN QS, 1994, IEEE T PATTERN ANAL, V16, P1156
  • [4] Registration of synthetic tomographic projection data sets using cross-correlation
    Fitchard, EE
    Aldridge, JS
    Reckwerdt, PJ
    Mackie, TR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (06) : 1645 - 1657
  • [5] 2-DIMENSIONAL REGISTRATION OF MAGNETIC-RESONANCE BRAIN IMAGES
    FITCHARD, EF
    NARAYANA, PA
    [J]. MEDICAL PHYSICS, 1994, 21 (08) : 1333 - 1337
  • [6] TOMOTHERAPY - A NEW CONCEPT FOR THE DELIVERY OF DYNAMIC CONFORMAL RADIOTHERAPY
    MACKIE, TR
    HOLMES, T
    SWERDLOFF, S
    RECKWERDT, P
    DEASY, JO
    YANG, J
    PALIWAL, B
    KINSELLA, T
    [J]. MEDICAL PHYSICS, 1993, 20 (06) : 1709 - 1719
  • [7] Calculation of portal dose using the convolution/superposition method
    McNutt, TR
    Mackie, TR
    Reckwerdt, P
    Papanikolaou, N
    Paliwal, BR
    [J]. MEDICAL PHYSICS, 1996, 23 (04) : 527 - 535
  • [8] PALTA JR, 1996, TELETHERAPY PRESENT
  • [9] RECKWERDT P, 1997, Patent No. 5673300
  • [10] Rosenfeld A., 1982, Digital Picture Processing, V1/2