In Situ Leg Length Measurement Technique in Hip Arthroplasty

被引:24
作者
Kurtz, William B.
机构
关键词
leg length; offset; hip arthroplasty; in situ measurement;
D O I
10.1016/j.arth.2011.02.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
In situ femoral preparation refers to implanting a femoral component before the femoral neck osteotomy and without dislocating the hip joint, which allows the implanted femoral component to be used to measure leg length and offset. One hundred hip arthroplasty surgeries among 93 patients were compared with a control group of 15 patients. A modular neck femoral component was implanted in a technique similar to implanting a femoral nail. The differences between the in situ measurements and the preoperative and postoperative radiograph measurements averaged -0.1 mm for leg length (r = 0.89) and -0.37 mm for offset (r = 0.57). In situ leg length measurement allows accurate measurement of leg length and offset and guides surgeons in selecting appropriate modular components to attain a near anatomical hip arthroplasty.
引用
收藏
页码:66 / 73
页数:8
相关论文
共 16 条
[1]
Bose WJ, 2000, ORTHOPEDICS, V23, P433
[2]
DANGLES CJ, J ARTHROPLA IN PRESS
[3]
The value of preoperative planning for total hip arthroplasty [J].
Eggli, S ;
Pisan, M ;
Muller, ME .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (03) :382-390
[4]
HARRIS WH, 1975, CLIN ORTHOP RELAT RE, V19
[5]
Hofmann Aaron A, 2008, Am J Orthop (Belle Mead NJ), V37, P18
[6]
JASTY M, 1996, CLIN ORTHOP RELAT RE, V165
[7]
KNIGHT WE, 1977, CLIN ORTHOP RELAT RE, V27
[8]
MCGEE HM, 1985, CLIN ORTHOP RELAT RE, V269
[9]
Acute sciatic and femoral neuritis following total hip arthroplasty - A case report [J].
Mihalko, WM ;
Phillips, MJ ;
Krackow, KA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (04) :589-592
[10]
MURPHY SB, CLIN ORTHOP RELAT RE, P160