Patient-maintained sedation for ERCP with a target-controlled infusion of propofol: a pilot study

被引:93
作者
Gillham, MJ
Hutchinson, RC
Carter, R
Kenny, GNC
机构
[1] Univ Glasgow, Royal Infirm, Dept Anaesthesia, Glasgow G31 2ER, Lanark, Scotland
[2] Royal Infirm, Dept Upper GI & Pancreat Biliary Surg, Glasgow G31 2ER, Lanark, Scotland
关键词
D O I
10.1067/mge.2001.116358
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: ERCP requires patient cooperation and often prolonged sedation. In different areas of anesthetic practice, patient-controlled sedation with a target-controlled infusion (TCI) of propofol provides effective sedation. The aim of this study was to assess the safety and efficacy of the same system in patients undergoing ERCP. Methods: Twenty patients used the TCI system. Patients received oxygen at 2 L/min via nasal cannulae, By using pharmacokinetic TCI software modeling, an initial propofol target blood concentration (Ct) of 1.0 mug/mL was supplemented on patient demand with a handset that, when pressed twice within 1 second, increased the Ct of propofol by 0.2 mug/mL. The maximum permissible target concentration was set at 3.0 mug/mL to prevent oversedation, Results: Sixteen patients used the system successfully throughout the procedure. The Ct propofol ranged from 1.2 to 2.6 mug/mL, and the number of successful handset activations (after commencement of the ERCP) ranged from 0 to 3, In 3 patients, the ceiling Ct propofol was attained without adequate sedation and the system was manually overridden. The system failed in 1 case because of patient confusion. There were no episodes of hemodynamic instability, airway obstruction, or significant oxygen desaturation, Endoscopist and patient satisfaction were high. Four patients were oversedated according to our criteria at the end of the procedure, but all were awake within 5 minutes of arrival in the recovery area. Conclusions: Patient-maintained sedation with TCI propofol was safe and fully effective in 16 patients. Ease of endoscopy was rated high by the endoscopists, and all patients were well satisfied with their sedation. Adjustments to the software programming are being evaluated to increase the safety profile to avoid oversedation.
引用
收藏
页码:14 / 17
页数:4
相关论文
共 15 条
[1]  
BELL GD, 1990, ALIMENT PHARM THERAP, V4, P103
[2]   SEDATION FOR UPPER GASTROINTESTINAL ENDOSCOPY - A COMPARATIVE-STUDY OF PROPOFOL AND MIDAZOLAM [J].
CARLSSON, U ;
GRATTIDGE, P .
ENDOSCOPY, 1995, 27 (03) :240-243
[3]   MONITORING AND SUPPLEMENTAL OXYGEN DURING ENDOSCOPY [J].
CHARLTON, JE .
BRITISH MEDICAL JOURNAL, 1995, 310 (6984) :886-887
[4]   PROPOFOL FOR SEDATION DURING ENDOSCOPY - ASSESSMENT OF A COMPUTER-CONTROLLED INFUSION SYSTEM [J].
CHURCH, JA ;
STANTON, PD ;
KENNY, GNC ;
ANDERSON, JR .
GASTROINTESTINAL ENDOSCOPY, 1991, 37 (02) :175-179
[5]  
Dubois A, 1988, Anaesthesia, V43 Suppl, P75, DOI 10.1111/j.1365-2044.1988.tb09078.x
[6]   CONSCIOUS SEDATION FOR GASTROSCOPY - PATIENT TOLERANCE AND CARDIORESPIRATORY PARAMETERS [J].
FROEHLICH, F ;
SCHWIZER, W ;
THORENS, J ;
KOHLER, M ;
GONVERS, JJ ;
FRIED, M .
GASTROENTEROLOGY, 1995, 108 (03) :697-704
[7]   Patient-maintained propofol sedation - Assessment of a target-controlled infusion system [J].
Irwin, MG ;
Thompson, N ;
Kenny, GNC .
ANAESTHESIA, 1997, 52 (06) :525-530
[8]   Patient-maintained propofol sedation as premedication in day-case surgery: assessment of a target-controlled system [J].
Murdoch, JAC ;
Kenny, GNC .
BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 (03) :429-431
[9]   Cardiovascular responses, arterial oxygen saturation and plasma catecholamine concentration during upper gastrointestinal endoscopy using conscious sedation with midazolam or propofol [J].
Oei-Lim, VLB ;
Kalkman, CJ ;
Bartelsman, JFWM ;
Res, JCJ ;
van Wezel, HB .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 1998, 15 (05) :535-543
[10]   PROPOFOL SEDATION FOR OUTPATIENT UPPER GASTROINTESTINAL ENDOSCOPY - COMPARISON WITH MIDAZOLAM [J].
PATTERSON, KW ;
CASEY, PB ;
MURRAY, JP ;
OBOYLE, CA ;
CUNNINGHAM, AJ .
BRITISH JOURNAL OF ANAESTHESIA, 1991, 67 (01) :108-111