Role of different loading conditions on resorption of hydroxyapatite coating evaluated by histomorphometric and stereological methods

被引:66
作者
Overgaard, S
Soballe, K
Josephsen, K
Hansen, ES
Bunger, C
机构
[1] AARHUS UNIV HOSP,FAC HLTH SCI,INST EXPT CLIN RES,DK-8200 AARHUS N,DENMARK
[2] AARHUS UNIV HOSP,FAC HLTH SCI,STEREOL RES LAB,DK-8200 AARHUS N,DENMARK
[3] AARHUS UNIV HOSP,FAC HLTH SCI,ROYAL DENT COLL,DEPT DENT PATHOL,DK-8200 AARHUS N,DENMARK
关键词
D O I
10.1002/jor.1100140607
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The role of different loading conditions on resorption of plasma-sprayed hydroxyapatite coating was investigated in an experimental study. Resorption of hydroxyapatite was quantified by histomorphometric and stereological methods on backscattered scanning electron images. Hydroxyapatite-coated titanium implants were inserted unilaterally into the medial femoral condyle of the knee in 14 mature dogs. Initially, all implants were subjected to controlled micromotion of 150 mu m. After 4 weeks, the dogs were randomly assigned either to have the implant surgically immobilized to prevent further micromovement or to have a sham operation. Sixteen weeks after the first operation, the implants were analyzed. Six noninserted implants served as controls. The surface area and volume of the hydroxyapatite coating were reduced on the immobilized implants by 53 and 67% (p < 0.05), respectively, and were further significantly reduced on the continuously loaded implants by 83 and 87%, respectively, compared with the control implants. The hydroxyapatite coating was significantly thinner on immobilized (15 mu m) and continuously loaded (15 mu m) implants as compared with control implants (23 mu m), but no difference between the inserted implants was found. Areas not covered with hydroxyapatite had 29 and 24% bone coverage on the immobilized and continuously loaded implants (not significant). Resorption of hydroxyapatite coating did occur in vivo. Continuous loading of the implants accelerated resorption significantly compared with immobilization of the implants. It is suggested that completely resorbed hydroxyapatite was partly replaced by bone in direct contact with the metal implant surface.
引用
收藏
页码:888 / 894
页数:7
相关论文
共 40 条
[1]  
BLOEBAUM RD, 1994, CLIN ORTHOPAEDICS, V298, P19
[2]  
Buckwalter J A, 1996, Instr Course Lect, V45, P387
[3]  
Buckwalter J A, 1996, Instr Course Lect, V45, P371
[4]  
CAPELLO WN, 1994, ORTHOPEDICS, V17, P781
[5]   BONE RESPONSE TO HYDROXYAPATITE-COATED AND COMMERCIALLY PURE TITANIUM IMPLANTS IN THE HUMAN ARTHRITIC KNEE [J].
CARLSSON, L ;
REGNER, L ;
JOHANSSON, C ;
GOTTLANDER, M ;
HERBERTS, P .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1994, 12 (02) :274-285
[6]  
COOK SD, 1988, CLIN ORTHOP RELAT R, V232, P225
[7]   IN-VIVO MECHANICAL AND HISTOLOGICAL CHARACTERISTICS OF HA-COATED IMPLANTS VARY WITH COATING VENDOR [J].
DALTON, JE ;
COOK, SD .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (02) :239-245
[8]   A HISTOLOGICAL AND HISTOMORPHOMETRICAL INVESTIGATION OF FLUORAPATITE, MAGNESIUMWHITLOCKITE, AND HYDROXYLAPATITE PLASMA-SPRAYED COATINGS IN GOATS [J].
DHERT, WJA ;
KLEIN, CPAT ;
JANSEN, JA ;
VANDERVELDE, EA ;
VRIESDE, RC ;
ROZING, PM ;
DEGROOT, K .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (01) :127-138
[9]  
FALLON MD, 1984, CALCIFIED TISSUE INT, V36, P458
[10]   THE SYNOVIAL-LIKE MEMBRANE AT THE BONE-CEMENT INTERFACE IN LOOSE TOTAL HIP REPLACEMENTS AND ITS PROPOSED ROLE IN BONE LYSIS [J].
GOLDRING, SR ;
SCHILLER, AL ;
ROELKE, M ;
ROURKE, CM ;
ONEILL, DA ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1983, 65 (05) :575-584