Salvage of long-term central venous catheters during an outbreak of Pseudomonas putida and Stenotrophomonas maltophilia infections associated with contaminated heparin catheter-lock solution

被引:38
作者
Dias, M. Beatriz Souza [1 ]
Habert, Alina Bernardes [2 ,3 ,4 ]
Borrasca, Vera [1 ]
Stempliuk, Valeska [1 ]
Ciolli, Aina [1 ]
Araujo, M. Rita E. [1 ]
Costa, Silvia F. [2 ,3 ,4 ]
Levin, Anna S. [1 ]
机构
[1] Univ Sao Paulo, Hosp Sirio Libanes, Infect Control Dept, Sao Paulo, Brazil
[2] Univ Sao Paulo, Infect Control Dept, Sao Paulo, Brazil
[3] Univ Sao Paulo, Hosp Clin, LIM 54, Sao Paulo, Brazil
[4] Univ Sao Paulo, Dept Infect Dis, Sao Paulo, Brazil
关键词
D O I
10.1086/526440
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
objective. To describe the management of patients with long-term central venous catheters (CVCs) during an outbreak of infection due to Pseudomonas putida and Stenotrophomonas maltophilia associated with contaminated heparin catheter-lock solution. design. Descriptive study. setting. Private, 250-bed tertiary-care hospital. methods. In March 2003, we identified 2 febrile cancer patients with P. putida bacteremia. Over 2 days, 7 cases of bacteremia were identified; lots of syringes prefilled with heparin catheter-lock solution, supplied by a compounding pharmacy, were recalled and samples were cultured. More cases of bacteremia appeared during the following days, and any patient who had had a catheter lock infused with the suspect solution was asked to provide blood samples for culture, even if the patient was asymptomatic. Isolates that were recovered from culture were typed by pulsed-field gel electrophoresis. Antimicrobial salvage treatment of long-term CVCs was attempted. results. A total of 154 patients had had their catheter lock infused with solution from the lots that were suspected of being contaminated. Only 48 of these patients had CVCs. By day 7 of the outbreak, 18 of these patients had become symptomatic. Twenty-six of the remaining 30 asymptomatic patients then also provided blood samples for culture, 10 of whom developed fever shortly after samples were collected. Thirty-two patients were identified who had P. putida bacteremia; 9 also had infection due to S. maltophilia. Samples from 1 of the 3 lots of prefilled syringes in use at the time of the outbreak also grew P. putida on culture. Molecular typing identified 3 different clones of P. putida from patients and heparin catheter-lock solution, and 1 clone of S. maltophilia. A total of 27 patients received antimicrobial therapy regimens, some of which included decontamination of the catheter lock with anti- infective lock solution. Of 27 patients, 19 (70%) retained their long-term CVC during the 6-month follow-up period. conclusions. To our knowledge, this is one of the largest prospective experiences in the management of bloodstream infection associated with long-term CVCs. The infections were caused by gram-negative bacilli and were managed without catheter removal, with a high response rate. We emphasize the risks of using intravenous formulations of medications supplied by compounding pharmacies that produce large quantities of drugs.
引用
收藏
页码:125 / 130
页数:6
相关论文
共 32 条
[1]  
Albo Lopez Carmen, 1999, Sangre (Saragossa), V44, P176
[2]   Two consecutive outbreaks of Stenotrophomonas maltophilia (Xanthomonas maltophilia) in an intensive-care unit defined by restriction fragment-length polymorphism typing [J].
Alfieri, N ;
Ramotar, K ;
Armstrong, P ;
Spornitz, ME ;
Ross, G ;
Winnick, J ;
Cook, DR .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 1999, 20 (08) :553-556
[3]  
Anonymous, 2005, Morbidity and Mortality Weekly Report, V54, P269
[4]  
[Anonymous], 1989, Molecular Cloning
[5]  
*ANVISA, 2006, 214 RDC
[6]   Pseudomonas aeruginosa and Pseudomonas putida outbreak associated with contaminated water outlets in an oncohaematology paediatric unit [J].
Aumeran, C. ;
Paillard, C. ;
Robin, F. ;
Kanold, J. ;
Baud, O. ;
Bonnet, R. ;
Souweine, B. ;
Traore, O. .
JOURNAL OF HOSPITAL INFECTION, 2007, 65 (01) :47-53
[7]   Totally implantable central venous access ports for long-term chemotherapy - A prospective study analyzing complications and costs of 333 devices with a minimum follow-up of 180 days [J].
Biffi, R ;
de Braud, E ;
Orsi, E ;
Pozzi, S ;
Mauri, S ;
Goldhirsch, A ;
Nole, F ;
Andreoni, B .
ANNALS OF ONCOLOGY, 1998, 9 (07) :767-773
[8]  
*CDCP, 2002, MMWR-MORBID MORTAL W, V51, P1109
[9]   Clinical management of catheter-related infections [J].
Fätkenheuer, G ;
Cornely, O ;
Seifert, H .
CLINICAL MICROBIOLOGY AND INFECTION, 2002, 8 (09) :545-550
[10]   Nosocomial Stenotrophomonas maltophilia cross-infection:: Three cases in newborns [J].
Gulcan, H ;
Kuzucu, C ;
Durmaz, R .
AMERICAN JOURNAL OF INFECTION CONTROL, 2004, 32 (06) :365-368