Transvaginal color Doppler sonography in adnexal masses: Which parameter performs best

被引:48
作者
Alcazar, JL
RuizPerez, ML
Errasti, T
机构
[1] Department of Obstetrics and Gynecology, Clínica Universitaria de Navarra, University of Navarre, Pamplona
[2] Department of Obstetrics and Gynecology, Clínica Universitaria de Navarra, 31080 Pamplona, Avda Pio XII s/n
关键词
transvaginal sonography; color Doppler; adnexal mass;
D O I
10.1046/j.1469-0705.1996.08020114.x
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aim of this study was to establish which of several commonly used parameters performs best in the evaluation of adnexal masses by transvaginal color Doppler sonography. A total of 79 adnexal masses in 73 consecutive patients were included in the study. There were 43 (58.9%) premenopausal and 30 (41.1%) postmenopausal patients. The median age was 45 years (range 20-78 years). The parameters compared were: number of vessels detected in each tumor, tumor vessel location (central vs. peripheral), peak systolic velocity (PSV), lowest resistance index (RI(lowest)), mean resistance index (RI(mean), lowest pulsatility index (PIlowest) and mean pulsatility index (PImean). Receiver operating characteristic (ROC) curves were plotted to analyze the test performance of the parameters, except for tumor vessel location, and to estimate the best cut-off value of the parameters studied to differentiate between malignant and benign tumors. Definitive histopathological diagnosis was obtained in every case and used as the 'gold standard'. There were 20 (25.3%) malignant and 59 (74.7%) benign masses. Color Doppler signals were detected in 100% of the malignant masses (20 out of 20) and 74.6% (44 out of 59) of the benign masses, and the difference was found to be statistically significant (p < 0.001). Tumor vessel location was central in 18 out of 20 (90%) malignant masses, whereas it was peripheral in 39 out of 44 (88.6%) benign masses. ROC analysis showed that the best cut-off values for number of vessels, PSV, RI(lowest), RI(mean), PIlowest and PImean were three vessels, 25 cm/s, 0.45, 0.55, 0.90 and 1.50, respectively. However, for all these parameters except RI(lowest), there was a considerable overlap between benign and malignant tumors, with a high false positive rate. In conclusion, in our experience, the parameters that performed best were the RI(lowest) with a cut-off value of 0.45 (sensitivity 100%; false-positive rate 11.4%) and central tumor vessel location (sensitivity 90%; false-positive rate 11.4%).
引用
收藏
页码:114 / 119
页数:6
相关论文
共 26 条
[1]  
[Anonymous], 1973, INT HISTOLOGICAL CLA
[2]  
BROMLEY B, 1994, OBSTET GYNECOL, V83, P434
[3]   OVARIAN MASSES - CAN BENIGN AND MALIGNANT LESIONS BE DIFFERENTIATED WITH COLOR AND PULSED DOPPLER US [J].
BROWN, DL ;
FRATES, MC ;
LAING, FC ;
DISALVO, DN ;
DOUBILET, PM ;
BENSON, CB ;
WAITZKIN, ED ;
MUTO, MG .
RADIOLOGY, 1994, 190 (02) :333-336
[4]   COLOR DOPPLER ULTRASONOGRAPHY AND SERUM CA-125 IN THE DIFFERENTIATION OF BENIGN AND MALIGNANT OVARIAN-TUMORS [J].
CHOU, CY ;
CHANG, CH ;
YAO, BL ;
KUO, HC .
JOURNAL OF CLINICAL ULTRASOUND, 1994, 22 (08) :491-496
[5]  
FLEISCHER AC, 1991, J ULTRAS MED, V10, P563
[6]  
FLEISCHER AC, 1993, J ULTRAS MED, V12, P41
[7]  
FURJAK A, 1991, J ULTRAS MED, V10, P295
[8]   TUMORS IN THE LOWER PELVIS AS IMAGED BY VAGINAL SONOGRAPHY [J].
GRANBERG, S ;
NORSTROM, A ;
WIKLAND, M .
GYNECOLOGIC ONCOLOGY, 1990, 37 (02) :224-229
[9]   HIGHEST OR LOWEST VALUES OF IMPEDANCE FLOW IN MALIGNANCY [J].
HALL, GM .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1991, 1 (05) :374-374
[10]   TRANSVAGINAL COLOR DOPPLER SONOGRAPHY OF ADNEXAL MASSES - DIFFERENCES IN BLOOD-FLOW IMPEDANCE IN BENIGN AND MALIGNANT LESIONS [J].
HAMPER, UM ;
SHETH, S ;
ABBAS, FM ;
ROSENSHEIN, NB ;
ARONSON, D ;
KURMAN, RJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (06) :1225-1228