Electrochemical molecular analysis without nucleic acid amplification

被引:108
作者
Gau, V
Ma, SC
Wang, H
Tsukuda, J
Kibler, J
Haake, DA
机构
[1] GeneFluid Inc, Monterrey Pk, CA 91754 USA
[2] Vet Affairs Greater Los Angeles Healthcare Syst, Los Angeles, CA 90073 USA
[3] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA 90095 USA
关键词
electrochemical detection; cyclic enzymatic reaction; bionanotechnology; genetic assay; immunoassay; simultaneous multi-channel detection;
D O I
10.1016/j.ymeth.2005.05.008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Electrochemical biosensors have revolutionized glucose monitoring but have not yet fulfilled their promise of a low cost, direct detection replacement for genetic amplification tests such as PCR [K. Kerman, M. Kobayashi, E. Tamiya, Recent trends in electrochemical DNA biosensor technology, Meas. Sci. Technol. 15 (2004) R1-R11; A. Chaubey, B.D. Malhotra, Mediated biosensors. Biosens. Bioelectron. 17 (6-7) (2002) 441-456]. It has been anticipated that the integration of nanoscale chemical structures such as self-assembled monolayers with electrochemical biosensors would increase sensitivity by decreasing inherent system noise. We have designed a novel biosensing approach incorporating such integration and achieved rapid, ultra-low concentration sensitivities without target amplification. Raw samples are mixed with lysis buffer to allow hybridization of nucleic acid targets with anchor and signal probes before immobilizing a signaling enzyme proximate to the biosensor surface. A bias potential is subsequently applied and the secondary byproduct of a cyclic peroxidase reaction measured. Further studies have demonstrated the application of our approach in protein, clinical chemistry, and ionic assays. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:73 / 83
页数:11
相关论文
共 12 条
[1]   Mediated biosensors [J].
Chaubey, A ;
Malhotra, BD .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) :441-456
[2]  
DRUMMOND G, 2003, NAT BIOTECHNOL, V21
[3]   Recent trends in electrochemical DNA biosensor technology [J].
Kerman, K ;
Kobayashi, M ;
Tamiya, E .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (02) :R1-R11
[4]   Patterning ligands on reactive SAMs by microcontact printing [J].
Lahiri, J ;
Ostuni, E ;
Whitesides, GM .
LANGMUIR, 1999, 15 (06) :2055-2060
[5]  
MACKAY I, 2002, NUCL ACIDS RES, V30
[6]   Recent developments, characteristics, and potential applications of electrochemical biosensors [J].
Mehrvar, M ;
Abdi, M .
ANALYTICAL SCIENCES, 2004, 20 (08) :1113-1126
[7]   Molecular recognition on functionalized self-assembled monolayers of alkanethiols on gold [J].
Motesharei, K ;
Myles, DC .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1998, 120 (29) :7328-7336
[8]   Self-assembled carbohydrate monolayers: Formation and surface selective molecular recognition [J].
Revell, DJ ;
Knight, JR ;
Blyth, DJ ;
Haines, AH ;
Russell, DA .
LANGMUIR, 1998, 14 (16) :4517-4524
[9]   Peroxidase-modified electrodes: Fundamentals and application [J].
Ruzgas, T ;
Csoregi, E ;
Emneus, J ;
Gorton, L ;
MarkoVarga, G .
ANALYTICA CHIMICA ACTA, 1996, 330 (2-3) :123-138
[10]   Rapid, species-specific detection of uropathogen 16S rDNA and rRNA at ambient temperature by dot-blot hybridization and an electrochemical sensor array [J].
Sun, CP ;
Liao, JC ;
Zhang, YH ;
Gau, V ;
Mastali, M ;
Babbitt, JT ;
Grundfest, WS ;
Churchill, BM ;
McCabe, ERB ;
Haake, DA .
MOLECULAR GENETICS AND METABOLISM, 2005, 84 (01) :90-99