Spatio-temporal fMRI analysis using Markov random fields

被引:89
作者
Descombes, X [1 ]
Kruggel, F [1 ]
von Cramon, DY [1 ]
机构
[1] Max Planck Inst Cognit Neurosci, D-04103 Leipzig, Germany
关键词
Bayesian framework; functional magnetic resonance imaging (fMRI) analysis; Markov random fields (MRF's); signal analysis; signal restoration;
D O I
10.1109/42.746636
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Functional magnetic resonance images (fMRI's) provide high-resolution datasets which allow researchers to obtain accurate delineation and sensitive detection of activation areas involved in cognitive processes. To preserve the resolution of this noninvasive technique, refined methods are required in the analysis of the data. In this paper, we first discuss the widely used methods based on a statistical parameter map (SPM) analysis exposing the different shortcomings of this approach when considering high-resolution data, First, the often used Gaussian filtering results in a blurring effect and in delocalization of the activated area. Secondly, the SPM approach only considers false alarms due to noise but not rejections of activated voxels. We propose to embed the fMRI analysis problem into a Bayesian framework consisting of two steps: i) data restoration and ii) data analysis, We, therefore, propose two Markov random fields (MRF's) to solve these two problems. Results on three protocols (visual, motor and word recognition) are shown for two SPM-approaches and compared with the proposed MRF-approach.
引用
收藏
页码:1028 / 1039
页数:12
相关论文
共 39 条
[1]  
[Anonymous], 1993, MARKOV RANDOM FIELDS
[2]  
[Anonymous], CHAMPS ALEATOIRES RE
[3]   FUNCTIONAL MAPPING OF THE HUMAN VISUAL-CORTEX BY MAGNETIC-RESONANCE-IMAGING [J].
BELLIVEAU, JW ;
KENNEDY, DN ;
MCKINSTRY, RC ;
BUCHBINDER, BR ;
WEISSKOFF, RM ;
COHEN, MS ;
VEVEA, JM ;
BRADY, TJ ;
ROSEN, BR .
SCIENCE, 1991, 254 (5032) :716-719
[4]  
BESAG J, 1974, ACAD ROYAL STAT SOC, V36, P721
[5]   Statistical methods of estimation and inference for functional MR image analysis [J].
Bullmore, E ;
Brammer, M ;
Williams, SCR ;
Rabehesketh, S ;
Janot, N ;
David, A ;
Mellers, J ;
Howard, R ;
Sham, P .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (02) :261-277
[6]   MODELING AND SEGMENTATION OF NOISY AND TEXTURED IMAGES USING GIBBS RANDOM-FIELDS [J].
DERIN, H ;
ELLIOTT, H .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (01) :39-55
[7]  
Descombes X., 1997, Traitement du Signal, V14, P373
[8]  
Descombes X., 1995, P 9 SCIA 95 UPPS SWE, P349
[9]   IMPROVED ASSESSMENT OF SIGNIFICANT ACTIVATION IN FUNCTIONAL MAGNETIC-RESONANCE-IMAGING (FMRI) - USE OF A CLUSTER-SIZE THRESHOLD [J].
FORMAN, SD ;
COHEN, JD ;
FITZGERALD, M ;
EDDY, WF ;
MINTUN, MA ;
NOLL, DC .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :636-647
[10]  
Friston K J, 1994, Hum Brain Mapp, V1, P210, DOI 10.1002/hbm.460010306